Manual of Petroleum Measurement Standards Chapter 2—Tank Calibration Section 2D—Calibration of Upright Cylindrical Tanks Using the Internal Electrooptical Distance-ranging Method
NORM herausgegeben am 1.1.2021
Designation standards: API MPMS 2.2D-ed.1
Publication date standards: 1.1.2021
The number of pages: 19
Approximate weight : 57 g (0.13 lbs)
Country: American technical standard
Kategorie: Technische Normen API
API MPMS 2.2D, 1st Edition, August 2003 - Manual of Petroleum Measurement Standards Chapter 2—Tank Calibration Section 2D—Calibration of Upright Cylindrical Tanks Using the Internal Electrooptical Distance-ranging Method
This part specifes a method for the calibration of upright cylindrical tanks having diameters greater than 5 m by means of internal measurements using an electro-optical distance-ranging instrument, and for the subsequent compilation of tank capacity tables. This method is known as the internal electro-optical distance-ranging (EODR) method.
This part of Chapter 2 is not applicable to the calibration of abnormally deformed (e.g. dented) tanks or of noncircular tanks.
This part of Chapter 2 is applicable to tanks tilted by < or = 3 % from the vertical, provided a correction is applied for the measured tilt as described in Chapter 2.2A.
This part of Chapter 2 is applicable to tanks with coneup or cone-down bottoms, as well as to tanks with flat bottoms.