Manual of Petroleum Measurement Standards Chapter 19.1 Evaporative Loss from Fixed-roof Tanks
Name übersetzen
NORM herausgegeben am 1.6.2022
Bezeichnung normen: API MPMS 19.1-ed.5
Ausgabedatum normen: 1.6.2022
SKU: NS-1139551
Zahl der Seiten: 38
Gewicht ca.: 114 g (0.25 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen API
API MPMS 19.1, 5th Edition, June 2017 - Manual of Petroleum Measurement Standards Chapter 19.1 Evaporative Loss from Fixed-roof Tanks
This standard contains methodologies for estimating the total evaporative losses of hydrocarbons from fixed-roof tanks. The methodologies provide loss estimates for general equipment types based on laboratory, test-tank, and field-tank data.
Types of fixed-roof tanks and roof fittings described are for information only.
The equations estimate average annual losses from fixed-roof tanks for various liquid stocks, stock vapor pressures, tank sizes, meteorological conditions, and operating conditions.
The following special cases are addressed:
The estimation may be improved by using detailed field information, including climatic data and operational data for the appropriate time period.
The equations are not intended to be used in the following applications:
The estimation procedures were developed to provide estimates of typical losses from fixed-roof tanks that are properly maintained and are in normal working condition. Losses from poorly maintained tanks may be greater. Because the loss equations are based on equipment conditions that represent a large population of tanks, a loss estimate for a group of fixed-roof tanks may be more representative than a loss estimate for an individual tank.
Evaporative loss considerations are not the only criteria for equipment selection. Many other factors not addressed in this standard, such as tank operation, maintenance, and safety, are important in designing and selecting tank equipment for a given application.
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-07-11 (Zahl der Positionen: 2 208 012)
© Copyright 2025 NORMSERVIS s.r.o.