Liquid Release Prevention and Detection Measures for Aboveground Storage Facilities
Name übersetzen
NORM herausgegeben am 1.10.1997
Bezeichnung normen: API PUBL 340-ed.1997
Ausgabedatum normen: 1.10.1997
SKU: NS-1139728
Zahl der Seiten: 105
Gewicht ca.: 346 g (0.76 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen API
API PUBL 340, 1997 Edition, October 1997 - Liquid Release Prevention and Detection Measures for Aboveground Storage Facilities
SCOPE OF REPORT
This report outlines the range of available procedures, technologies, and equipment that can be used to prevent and/or detect liquid releases at existing aboveground storage tank facilities. It is intended to assist in the selection of appropriate options to prevent or detect releases and to protect the environment should a release occur. Additionally, the control measures have been identified according to their ability to prevent or detect types of releases and to protect the environment in the event of a release. Emphasis is given to release prevention measures.
The storage components addressed include: tankage, facility piping, loading and unloading areas, ancillary equipment (e.g., vapor processing, additive systems, sumps), and facility operating systems. These components are illustrated in Figure 1-1. For each of these components, the report:
Additionally, the report gives an indication of the relative costs required to install or implement the various measures. These costs are intended to be used only as a basis for comparing control measures. Actual installation and implementation costs will vary depending onsite conditions, facility location, and regional cost factors.
Applicable federal and several state regulations were reviewed during preparation of this document. However, specific regulatory requirements or citations are not discussed, as they are subject to change and may not be universally applicable. Similarly, this report does not address regulatory requirements that may be required by local jurisdictions. Federal, state and local requirements should betaken into consideration in selecting a control measure.
At the time this report was prepared, new release prevention technologies were being developed. Most of these are not listed in the report because their performance has not been thoroughly validated; however, some emerging technologies have been highlighted in the tables for the readers information. The reader should confirm the suitability and effectiveness of these new technologies prior to using them.
This report does not cover:
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-08-01 (Zahl der Positionen: 2 211 585)
© Copyright 2025 NORMSERVIS s.r.o.