Results of Range-Finding Testing of Leak Detection and Leak Location Technologies for Underground Pipelines
Name übersetzen
NORM herausgegeben am 1.11.1998
Bezeichnung normen: API PUBL 346-ed.1998
Ausgabedatum normen: 1.11.1998
SKU: NS-1139734
Zahl der Seiten: 239
Gewicht ca.: 748 g (1.65 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen API
API PUBL 346, 1998 Edition, November 1998 - Results of Range-Finding Testing of Leak Detection and Leak Location Technologies for Underground Pipelines
SCOPE AND OBJECTIVES
The project objectives were to:
The scope of the project was limited to range-finding tests; testing was not intended to provide a complete evaluation of any specific system. Rather, the objective was to identify technologies and obtain information on the performance of each technology, together with the field considerations or limitations for applying each.
GENERAL PROJECT OBJECTIVES
The project identified the different technologies available for leak detection and leak location for underground pipelines of the sort used at refineries, fuel terminals, airports, and transportation facilities. Four different technologies were identified and representative vendors of each were reviewed. Based on that review, a vendor of each technology was selected and invited to participate in field trials. The purpose of the field tests was to provide information on the state of the technology in terms of its suitability for use in the field and to provide and estimate each technologys sensitivity and accuracy in application.
SCOPE OF THE TESTING
The scope of the testing of each technology was designed to observe the operation of the technology and provide an approximate estimate of its performance. To this end, several features of each technology were documented as part of the testing:
Testing was conducted with different lengths of lines and with different simulated leak rates. Testing was conducted at an operating site, which included one line with a suspected leak and another line with a known substantial leak as well as two lines of different sizes that were supposed to be tight. Thus, the tests included both real leaks and simulated leaks and different length of lines, providing different volumes of product in the lines.
The vendors were provided with a description of the facility, including a sketch of the configuration of the lines. The approximate length of each identified segment was provided as well as the diameter and, when applicable, the number of hydrants. The vendors were told that the lines would be taken out of service and isolated from the rest of the system by blind flanges so that there would be no question about possible leakage past valves into other sections of the pipeline. MRI told the vendors that they were being asked to test each section of line as a commercial test and report the results. Vendors were told that all work performed would be considered their typical commercial protocol. If the vendors identified a leak in the lines as they found them, and had the capability of locating the leak, they would be asked to locate the leak.
MRI also told the vendors that they would be asked to test each line multiple times. MRI would simulate a number of leaks of various sizes during some of the testing and would ask the vendors to conduct a number of tests under both tight and simulated leak conditions. The simulated leak rates would be kept blind to the vendors.
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-08-01 (Zahl der Positionen: 2 211 585)
© Copyright 2025 NORMSERVIS s.r.o.