Verification and Validation of Subsea Connectors
Name übersetzen
NORM herausgegeben am 1.4.2017
Bezeichnung normen: API TR 17TR7-ed.1
Ausgabedatum normen: 1.4.2017
SKU: NS-1140698
Zahl der Seiten: 34
Gewicht ca.: 102 g (0.22 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen API
API TR 17TR7, 1st Edition, April 2017 - Verification and Validation of Subsea Connectors
This Technical Report provides requirements and recommendations for the verification and validation of subsea connectors. It is intended to serve as a common reference for designers, manufacturers, and users to improve the performance assessment of subsea connectors and to improve the reliability and integrity of subsea systems.
This technical report is applicable to subsea connectors along the vertical centerline of subsea hardware (i.e. tree, tubing head, tree cap, tree running tool, well control package connectors, and EDP connectors), the subsea wellhead, and the completion/workover riser. The methodology provided herein may also be used in other connector designs. Connectors outboard of the vertical centerline are addressed in API 17R.
The scope of this Technical Report includes connectors subjected to structural and pressure loads for wellhead, tree, tubing head, tree cap, tree running tool, and EDP connectors, and is intended to define general performance capacities for API 17D, API 17G, and other applications.
In the development of this Technical Report, verification and validation of casing and tubing connectors and welded connectors are recognized as ongoing work. At this time, casing and tubing connectors and welded connectors are not within the scope of this document and are deferred to their applicable specifications.
Differential external pressure effects are not within the scope of this document—refer to API 17TR12.
Fatigue verification through analysis is included. Fatigue testing of subsea connectors is not a mandatory requirement.
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-07-11 (Zahl der Positionen: 2 208 012)
© Copyright 2025 NORMSERVIS s.r.o.