Standard Specification for 19 Wire Combination Unilay-Stranded Copper Conductors for Subsequent Insulation
Automatische name übersetzung:
Standard-Spezifikation für 19 Drahtkombination Unilay Strang- Kupferleiter für spätere Isolierung
NORM herausgegeben am 10.11.2001
Bezeichnung normen: ASTM B787/B787M-01
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 10.11.2001
SKU: NS-8118
Zahl der Seiten: 5
Gewicht ca.: 15 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
copper electrical conductors-stranded, electrical performance, insulated wire and cable-insulation, mechanical testing, rated strength (electrical conductor wire), strength-general, unilay-stranded copper electrical conductors, nineteen wire unilay-stranded copper conductors (for subsequent, insulation), ICS Number Code 29.060.20 (Cables)
| 1. Scope | ||||||||||||||||||
|
1.1 This specification covers bare combination unilay-stranded conductors made from round copper wires, either uncoated or coated with tin or lead alloy for insulated conductors for electrical purposes. These conductors shall be constructed with a central core wire surrounded by two layers of helically laid wires, resulting in an outer diameter equal to the compressed-stranded equivalent conductor. (See Explanatory Note 1 and Note 2). Note 1—For the purpose of this specification, combination unilay conductor is defined as follows: a central core wire surrounded by a layer of six helically laid wires of the same diameter as the core wire with a helically laid outer layer containing six smaller wires alternated between six wires of the same diameter as the wires in the layer underneath. Both layers have a common length and direction of lay (see Fig 1). <>1.2 For the purpose of this specification, normal conductor classification (Class AA, A, B, C) is not applicable as these conductors are intended for subsequent insulation. The descriptive term combination unilay-stranded shall be used in place of conductor classification. 1.3 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. For conductor sizes designated by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values, stated or derived, in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units. 1.3.1 For density, resistivity, and temperature, the values stated in SI units are to be regarded as standard. |
||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-05-15 (Zahl der Positionen: 2 278 685)
© Copyright 2026 NORMSERVIS s.r.o.