Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Hydrostatic Infiltration Testing of Vitrified Clay Pipe Lines (Includes all amendments And changes 12/9/2013).
Automatische name übersetzung:
Standard Test Method for hydrostatische Infiltration Testing von Steinzeugrohrleitungen
NORM herausgegeben am 1.11.2008
Bezeichnung normen: ASTM C1091-03a(2008)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.11.2008
SKU: NS-9424
Zahl der Seiten: 2
Gewicht ca.: 6 g (0.01 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
air test, clay pipe, hydrostatic test, infiltration, pipe, pressure test, sewers, vitrified clay pipe, water test, Acceptance criteria/testing--clay pipe/fittings, Clay pipe/piping systems, Exfiltration rate, Field testing, Hydrostatic testing, Infiltration rate, Pressure testing--clay pipe, Pressure testing--pipes, Sewerlines, Standpipes, Vitrified clay pipe/fittings, Water analysis, Water supply/distribution systems, Water test, ICS Number Code 91.100.25 (Terracotta building products)
| Significance and Use | ||||||
|
The tests called for herein, for their results, indicate the acceptability of installed vitrified clay pipelines. |
||||||
| 1. Scope | ||||||
|
1.1 This test method defines procedures for hydrostatic infiltration testing of new installations of vitrified clay pipe lines, to demonstrate the structural integrity of the installed line. Refer to Practice C 12. 1.2 This test method is suitable for testing gravity-flow pipe lines constructed of vitrified clay pipe or combinations of clay pipe and other pipe materials. 1.3 This test method is applicable to the testing of the pipe lines only. Manholes or other structures should be tested separately. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||