Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Specification for Concrete Pipe for Irrigation or Drainage (Metric)
Automatische name übersetzung:
Standard-Spezifikation für Beton-Rohr für Bewässerungs- oder Entwässerungs (metrisch)
NORM herausgegeben am 1.9.2011
Bezeichnung normen: ASTM C118M-11
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.9.2011
SKU: NS-9925
Zahl der Seiten: 4
Gewicht ca.: 12 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
absorption, acceptance criteria, concrete, design, drainage, hydrostatic, irrigation, joints, manufacture, nonreinforced, pipe, pressure, tests, three-edge bearing: Concrete pipe (nonreinforced)--specifications, Irrigation piping--specifications, Land drainage piping systems
| 1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
1.1 This specification covers nonreinforced concrete pipe to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, as shown in Table 1 and for use in drainage. 1.2 This specification is the SI counterpart of Specification C118. Note 1—This specification is for manufacturing and purchase only and does not include requirements for bedding, backfill, installation, or field repairs. The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation. TABLE 1 Standard Dimensions, Working Pressure, and Test Requirements for Standard Concrete Irrigation PipeA
A For hydrostatic test requirements, refer to 10.5. B Higher working pressures are not prohibited up to a maximum of 120 kPa for 150 through 200-mm diameters, 105 kPa for 250 through 300-mm diameters, and 90 kPa for 350 through 600-mm diameters. In these cases, the strength of the pipe shall be increased to give a minimum internal hydrostatic test pressure of at least four times the design working pressure when tested as specified in 10.5. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-05-17 (Zahl der Positionen: 2 278 942)
© Copyright 2026 NORMSERVIS s.r.o.