Standard Test Method for Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method (Metric)
Automatische name übersetzung:
Standard Test Method for Betonrohr SEWERLINES durch Unterdruck (Vakuum ) Testverfahren (metrisch)
NORM herausgegeben am 1.1.2000
Bezeichnung normen: ASTM C1214M-94(2000)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.2000
SKU: NS-10072
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
cement-portland, mortar-cement mortar, silica, silica fume, silica fume for use in portland cement concrete/mortar, ICS Number Code 23.040.50 (Pipes and fittings of other materials)
| 1. Scope | ||||||
|
1.1 This test method covers procedures for testing concrete pipe sewerlines, when using the negative air pressure (vacuum) test method to demonstrate the integrity of the installed material and the construction procedures. This test method covers testing of 100 to 900-mm diameter circular concrete pipe sewerlines utilizing gasketed joints. 1.2 Methods described in this test method may also be used as a preliminary test to enable the manufacturer or installer to demonstrate the condition of sewer pipe prior to delivery or backfill. Minimum test times presented in are for pipelines. Holding times for testing an individual pipe may have to be increased to allow for the accumulation of leakage when the tested pipe are incorporated into a continuous pipeline. 1.3 This test method is the metric companion to Test Method C1214. Note 1--The negative air pressure (vacuum) test criteria presented in this test method are similar to those in general use. The test and criteria have been used widely and successfully in testing smaller diameter pipe. Larger pipe may be accepted more conveniently by visual inspection and individual joint testing. Note 2--It should be understood that no correlation has been found between loss of vacuum and water leakage. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 6 for specific safety precautions. |
||||||
| 2. Referenced Documents | ||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-05-17 (Zahl der Positionen: 2 278 942)
© Copyright 2026 NORMSERVIS s.r.o.