Standard Test Method for Determination of Impurities in Plutonium: Acid Dissolution, Ion Exchange Matrix Separation, and Inductively Coupled Plasma-Atomic Emission Spectroscopic (ICP/AES) Analysis
Automatische name übersetzung:
Standard Test Methode zur Bestimmung von Verunreinigungen in Plutonium: Säureauflösung , Ionenaustauschermatrix Trennung, und induktiv gekoppelte Plasma - Atomemissionsspektroskopie(ICP / AES ) Analyse
NORM herausgegeben am 10.6.1999
Bezeichnung normen: ASTM C1432-99
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 10.6.1999
SKU: NS-11235
Zahl der Seiten: 4
Gewicht ca.: 12 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
dissolution, inductively coupled plasma-atomic emission spectroscopy (ICP-AES), impurities in plutonium, ion exchange separation, plutonium, ICS Number Code 27.120.30 (Fissile materials and nuclear fuel technology)
1. Scope | ||||||||||||
1.1 This test method covers the determination of 25 elements in plutonium (Pu) materials. The Pu is dissolved in acid, the Pu matrix is separated from the target impurities by an ion exchange separation, and the concentrations of the impurities are determined by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). The elements determined are listed in Table 2. 1.2 This test method is specific for the determination of impurities in Pu in 8 M nitric acid (HNO3) solutions. Impurities in other plutonium materials, including plutonium oxide samples, may be determined if they are appropriately dissolved (see Practice C 1168) and converted to 8 M HNO3 solutions. 1.3 Plutonium bearing materials are radioactive and toxic. Adequate laboratory facilities, glove boxes, and fume hoods, along with safe techniques, must be used in handling samples containing these materials. A detailed discussion of all the precautions necessary is beyond the scope of this test method; however, personnel who handle these materials should be familiar with such safe handling practices. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||
2. Referenced Documents | ||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-05-02 (Zahl der Positionen: 2 896 910)
© Copyright 2024 NORMSERVIS s.r.o.