Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures, Pipes, and Laterals
Automatische name übersetzung:
Standard-Spezifikation für Gully Resilient Verbinder zwischen Stahlbeton Regenwasserkanal Structures , Pipes und Laterals
NORM herausgegeben am 1.3.2008
Bezeichnung normen: ASTM C1478-08
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.3.2008
SKU: NS-11446
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
design test method, marking, material requirements acceptance criteria, product marking, resilient connector, Concrete pipe (reinforced)--specifications, Laterals (concrete), Resilient connectors, Sewer pipe (concrete)--specifications, Storm sewer/drainage concrete pipe--specifications, ICS Number Code 23.040.50 (Pipes and fittings of other materials)
1. Scope | ||||||||||||||||||||||||||||||||
1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C 478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems. 1.1.1 These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are for information only. Note 1—This specification covers the design, material, and performance of the resilient connection only. Connections covered by this specification are adequate for hydrostatic pressures up to 6 psi (14 ft) without leakage when tested in accordance with Section 7. Infiltration quantities for an installed system are dependent upon many factors other than the connections between storm sewer structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system. 1.3 The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific warning statement, see 7.2.4. |
||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||
|
Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.