Standard Practice for Preparation of Field Removed Manufactured Masonry Units and Masonry Specimens for Testing
Automatische name übersetzung:
Standard Praxis für die Herstellung von Spielfeld entfernt Hergestellt Mauersteine und Mauerwerkskörper zur Prüfung
NORM herausgegeben am 1.7.2015
Bezeichnung normen: ASTM C1587/C1587M-15
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.7.2015
SKU: NS-611330
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
bond wrench, brick, compressive strength testing, concrete masonry unit, flexural bond strength testing, grout, hardened mortar, manufactured masonry units, masonry prisms, masonry specimens, mortar, preparation of masonry for testing, structural clay tile,, ICS Number Code 91.100.01 (Construction materials)
Significance and Use | ||||||||||||||
4.1 Masonry units and masonry specimens are sometimes removed as part of an assessment of the condition of masonry construction. This standard is intended to standardize the preparation of such units and masonry specimens for compressive and flexural bond strength testing. Note 1: Masonry specimens removed from existing masonry
construction (single wythe, multi-wythe or portions thereof) will
sometimes contain mortar, grout, reinforcement, or accessory
materials.
4.2 This practice provides information pertaining to the removal of hardened mortar, cleaning, and other special preparation required prior to compressive and flexural bond strength testing of a manufactured masonry unit or masonry specimen that has been removed from usage. 4.3 This practice does not address test procedures or the use of test results conducted on removed specimens. This practice does not determine whether removed masonry materials met original specification requirements. Note 2: Compressive and flexural bond strength test results of
masonry units and masonry specimens extracted from the field are
expected to vary from and will likely be less than test results of
masonry units that have not been placed in service or masonry
prisms that have been constructed within a controlled environment.
Comparison of results of tests conducted on specimens removed from
service to those of masonry units prior to use or of constructed
prisms is difficult. Considerable judgment is typically required
for the selection and preparation of specimens removed from
service.
|
||||||||||||||
1. Scope | ||||||||||||||
1.1 The purpose of this practice is to standardize the preparation of manufactured masonry units and masonry specimens extracted from the field for compressive and flexural bond strength testing in a laboratory environment. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The inch-pound units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|