Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Practice for Making and Curing Test Specimens for Evaluating Frost Resistance of Coarse Aggregate in Air-Entrained Concrete by Rapid Freezing and Thawing
Automatische name übersetzung:
Standard Praxis für die Herstellung und Lagerung von Prüfkörpern zur Bewertung Frostwiderstand der groben Gesteinskörnung in Air Porenbeton von Rapid Einfrieren und Auftauen
NORM herausgegeben am 15.1.2007
Bezeichnung normen: ASTM C1646/C1646M-07
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 15.1.2007
SKU: NS-12106
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
aggregate, coarse aggregate, freezing and thawing, frost resistance, ICS Number Code 91.100.30 (Concrete and concrete products)
| Significance and Use | ||||||||||||||||||||||||||
|
This practice provides standard requirements for evaluating frost-susceptible coarse aggregate in air-entrained concrete subjected to freezing and thawing in accordance with Test Method C 666/C 666M. Concrete containing frost-resistant paste may not be resistant to freezing and thawing if it contains coarse aggregate that becomes critically saturated. An aggregate particle is considered to be critically saturated when there is insufficient unfilled pore space to accommodate the expansion of water that accompanies the freezing. The potential of the coarse aggregate to cause damage due to cycles of freezing and thawing is evaluated by Test Method C 666/C 666M. |
||||||||||||||||||||||||||
| 1. Scope | ||||||||||||||||||||||||||
|
1.1 This practice covers procedures for making and curing test specimens for evaluating frost resistance of normal-weight coarse aggregates in air-entrained concrete in accordance with Test Method C 666/C 666M, Procedure A or B. 1.2 The values stated in either inch-pound or SI units shall be regarded separately as standard. The SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard. 1.3 This practice does not purport to address all the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning-Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged use.) |
||||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-06-11 (Zahl der Positionen: 2 281 927)
© Copyright 2026 NORMSERVIS s.r.o.