Standard Test Method for Continuity of Coatings in Glassed Steel Equipment by Electrical Testing (Includes all amendments And changes 12/31/2010).
Automatische name übersetzung:
Standard Test Method for Continuity of Coatings in glasierter Stahl Ausrüstung durch elektrische Prüfung
NORM herausgegeben am 1.8.2004
Bezeichnung normen: ASTM C536-83(2004)e1
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.8.2004
SKU: NS-13913
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
continuity of coating, discontinuities, glass coated steel equipment, glass coating, high voltage test, porcelain enamel, ICS Number Code 25.220.50 (Enamels)
| Significance and Use | ||
|
This test method is designed to detect existing discontinuities in the glass coating of glassed steel equipment while maintaining a voltage low enough as to be unlikely to cause breakdown of the coating. The test is adaptable for manufacturing inspection in the processing of equipment and for field use to find existing defects which can be “plugged” or repaired before serious damage is done to the equipment. As a means of positive detection, it is applicable to process studies, quality control, or specification. |
||
| 1. Scope | ||
|
1.1 This test method covers the detection of discontinuities in the glass coating of glassed steel equipment where such discontinuities would result in early failure due to the attack of the chemical contents of the vessel on the metal substrate. It is applicable to ( 1) provide a manufacturing and inspection test of glassed-steel equipment designed for relatively mild, low-temperature corrosive service, and (2) the field testing of similar equipment used in more severely corrosive environment. Note 1A manufacturing test method for the latter type of equipment is described in Test Method C 537. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||
| 2. Referenced Documents | ||
|