Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines
Automatische name übersetzung:
Standard Praxis für Infiltration und Exfiltration Abnahmeprüfung der installierten Betonfertigrohrabwasserleitungen
NORM herausgegeben am 1.6.2009
Bezeichnung normen: ASTM C969-02(2009)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.6.2009
SKU: NS-15896
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
Concrete pipe, Exfiltration rate, Filtration performance, Infiltration rate, Pond/canal/reservoir/ditch linings, Sewer pipe (concrete), Water analysis, Water infiltration/exfiltration, Water penetration, ICS Number Code 23.040.50 (Pipes and fittings of other materials)
| Significance and Use | ||
|
This is not a routine test. The values recorded are applicable only to the sewer being tested and at the time of testing. |
||
| 1. Scope | ||
|
1.1 This practice covers procedures for testing installed precast concrete pipe sewer lines using either water infiltration or exfiltration acceptance limits to demonstrate the integrity of the installed materials and construction procedure. 1.2 This practice is the inch-pound companion to Practice C 969M; therefore, no SI equivalents are presented in the practice. Note 1—The owner shall specify the following: who will conduct, observe, and furnish labor, furnish material and measuring devices, and pay for the tests; who is responsible for determining local groundwater conditions; and which test is to be conducted, that is, an infiltration test or an exfiltration test. Note 2—The user of this practice is advised that test criteria presented in this practice are similar to those in general use. Pipe, 24-in. diameter or larger, may be accepted by visual inspection when testing for infiltration. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||
| 2. Referenced Documents | ||
|
Historisch
1.7.2013
Historisch
1.2.2013
Historisch
1.2.2013
Historisch
1.2.2014
Historisch
1.2.2014
Historisch
1.2.2014
Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.
Aktualisierung 2x pro Monat!
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-07-08 (Zahl der Positionen: 2 286 190)
© Copyright 2026 NORMSERVIS s.r.o.