Standard Specification for Joints for IPS PVC Pipe Using Solvent Cement (Includes all amendments And changes 8/16/2017).
Automatische name übersetzung:
Standard-Spezifikation für Joints für IPS PVC-Rohr Mit Klebe
NORM herausgegeben am 1.1.1996
Bezeichnung normen: ASTM D2672-96a
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.1996
SKU: NS-21118
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
Bell/spigot pipe joints, Joints, pipe applications, Nonpressure piping, Poly(vinyl chloride)(PVC) fittings, Poly(vinyl chloride)(PVC) pipe, Sockets, Solvent cements for joining thermoplastic pipe/fittings, Spigot/bell pipe joints, joints for pressure/non-pressure IPS PVC pipe, ICS Number Code 23.040.20 (Plastic pipes)
| 1. Scope | ||||||||||||||||||||||||||
|
1.1 This specification covers the socket produced for solvent cement joints on both pressure and non-pressure IPS pipe. It also covers the testing of the joints on both pressure and non-pressure pipe, and includes requirements for socket dimensions, burst pressure, and joint tightness tests of the solvent cemented joints. The tests described are not intended for routine quality control, but rather to evaluate the performance characteristics of the joint. Note 1-On dual marked Schedule 40 DWV and potable water pipe, the socket bells must conform to the dimensional and physical requirements for pressure socket bells. 1.2 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification. 1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. Note 2-Changes in ground, water, or air temperature will produce expansion or contraction forces in PVC piping, and these will result in longitudinal shear stresses in the solvent cement joints. These stresses must be considered in the design and operation of the system. Note 3-See Methods D618 for information relating to this specification.1.4 The following safety hazards caveat pertains only to the test method portion, Section 9, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-08-06 (Zahl der Positionen: 2 291 512)
© Copyright 2026 NORMSERVIS s.r.o.