Standard Test Methods for Iodide and Bromide Ions in Brackish Water, Seawater, and Brines
Name übersetzen
NORM herausgegeben am 1.4.2023
Bezeichnung normen: ASTM D3869-15(2023)
Ausgabedatum normen: 1.4.2023
SKU: NS-1140809
Zahl der Seiten: 12
Gewicht ca.: 36 g (0.08 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
brackish, brine, bromide ion, colorimetric, iodide ion, selective electrode,, ICS Number Code 13.060.50 (Examination of water for chemical substances)
| Significance and Use | ||||||||||||||||||
|
4.1?Identification of a brackish water, seawater, or brine is determined by comparison of the concentrations of their dissolved constituents. The results are used to evaluate the origin of the water, determine if it is a possible pollutant or determine if it is a commercial source of a valuable constituent such as iodine or bromine. |
||||||||||||||||||
| 1. Scope | ||||||||||||||||||
|
1.1?These test methods2 cover the determination of soluble iodide and bromide ions, or both, in brackish water, seawater, and brines. Four test methods are given as follows: 1.1.1?Test Method A for both Iodide and Bromide IonsVolumetric, for concentrations from 0.2 mg/L to 2000 mg/L iodide and from 5 mg/L to 6500 mg/L bromide (Sections 7 15). 1.1.2?Test Method B for Iodide IonColorimetric, for concentrations from 0.2 mg/L to 2000 mg/L iodide (Sections 16 25). 1.1.3?Test Method C for Iodide IonSelective electrode, for concentrations from 1 mg/L to 2000 mg/L iodide (Sections 26 34). 1.1.4?Test Method D for Bromide IonColorimetric, for concentrations from 40 mg/L to 6500 mg/L bromide (Sections 35 44). 1.2?Test Method A is intended for use on all brackish waters, seawaters, and brines that contain appreciable amounts of iodide or bromide ions or both. Test Methods B, C, and D, because of their rapidity and sensitivity, are recommended for the analysis of brackish waters, seawaters, and brines in the field and in the laboratory. 1.3?Samples containing from 0.2 mg/L to 2000 mg/L of iodide or 5 mg/L to 6500 mg/L of bromide may be analyzed by these methods. 1.4?The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?