Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Determination of Vibrated Bulk Density of Calcined Petroleum Coke
Automatische name übersetzung:
Standard -Testverfahren zur Bestimmung von Schwingungen versetzt Rohdichte von calciniertem Petrolkoks
NORM herausgegeben am 1.5.2007
Bezeichnung normen: ASTM D4292-92(2007)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.5.2007
SKU: NS-26714
Zahl der Seiten: 4
Gewicht ca.: 12 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
calcined petroleum coke, porosity, vibrated bulk density, ICS Number Code 75.160.10 (Solid fuels)
| Significance and Use | ||||||||||||||||
|
Vibrated bulk density, VBD, is an indicator of calcined petroleum coke porosity, which affects its suitability for use in pitch-bonded carbon applications. (Warning—Vibrated bulk density for a sample of calcined petroleum coke is strongly dependent upon average particle size and particle size range. Bulk density tends to increase with decreasing coke size. A narrow particle size range for this test minimizes the possibility for variation due to skewing of the test sample toward either screen defining the sample. Particle size range tested should be agreed upon by the purchaser and supplier.) Note 1—An example of the use of VBD to characterize coke for prebaked anodes for aluminum smelting is reported by Belitskus3 who found particles passing through a 0.59-mm opening, No. 30, sieve and retained on a 0.30-mm opening, No. 50, sieve to be preferred. Other popular ranges are particles passing through a 2.36-mm opening, No. 8, sieve and retained on a 1.17-mm opening, No. 16, sieve for the continuous Soderberg anode process and particles passing through a 6.68-mm opening sieve (equivalent to a 3-mesh Tyler Standard Series) and retained on a 3.33-mm opening, No. 6, sieve for graphite electrode manufacture. |
||||||||||||||||
| 1. Scope | ||||||||||||||||
|
1.1 This test method covers the determination of bulk density of a representative 2-kg sample of calcined petroleum coke, after vibration to increase compaction. 1.2 The procedure is limited to particles passing through a 6.68-mm opening sieve (equivalent to a 3-mesh Tyler Standard Series) and retained on a 0.21-mm opening sieve (equivalent to a 65-mesh Tyler Standard Series). Further, the procedure is limited to a specific test sample having particles retained between screens having openings that differ by a factor of less than 2Equation 1 - 2 and preferably less than 2. 1.3 The values stated in acceptable SI units are to be regarded as the standard. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||
|
Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.
Aktualisierung 2x pro Monat!
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-08-31 (Zahl der Positionen: 2 298 775)
© Copyright 2026 NORMSERVIS s.r.o.