Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Chlordane and Heptachlor Residues in Indoor Air (Withdrawn 2011)
Automatische name übersetzung:
Standard Test Method for Chlordan und Heptachlor Rückstände in der Innenraumluft (Withdrawn 2011)
NORM herausgegeben am 1.3.2005
Bezeichnung normen: ASTM D4947-05
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.3.2005
SKU: NS-29243
Zahl der Seiten: 8
Gewicht ca.: 24 g (0.05 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
chlordane, electron capture detection, gas chromatography, heptachlor, indoor air, polyurethane foam, ICS Number Code 13.040.20 (Ambient atmospheres)
| Significance and Use | ||||||||||||||||
|
This test method is intended to be used primarily for non-occupational exposure monitoring in domiciles, public access buildings and offices. Chlordane has been used widely as a general insecticide for crops (for example, cotton) and as a termiticide. Heptachlor is a major component of technical chlordane and an insecticide in its own right. Although their use in the United States was discontinued in 1988, residues of the chemicals may remain in indoor air for many years after application. |
||||||||||||||||
| 1. Scope | ||||||||||||||||
|
1.1 This test method covers the sampling and analysis of indoor atmospheres for residues of chlordane and heptachlor. 1.2 This test method is based upon the collection of chlordane and heptachlor from air onto polyurethane foam (PUF) and analysis by gas chromatography coupled with electron capture detection. 1.3 This test method is applicable to concentrations of chlordane varying from 0.1 to 100 g/m3 and heptachlor varying from 0.01 to 80.0 g/m3 with sampling periods to collect at least 0.25 m3 of air. Detection limits will depend upon the conditions of the gas chromatography (GC) and the length of the sampling period. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-09-10 (Zahl der Positionen: 2 300 145)
© Copyright 2026 NORMSERVIS s.r.o.