Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Determination of Chloride, Nitrate, and Sulfate in Atmospheric Wet Deposition by Chemically Suppressed Ion Chromatography
Automatische name übersetzung:
Standard Test Methode zur Bestimmung von Chlorid, Nitrat und Sulfat in Atmospheric Wet Deposition von Chemisch suppressierter Ionenchromatographie
NORM herausgegeben am 1.1.1995
Bezeichnung normen: ASTM D5085-95
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.1995
SKU: NS-29779
Zahl der Seiten: 9
Gewicht ca.: 27 g (0.06 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
Anions content, Atmospheric analysis, Chloride content, Hail, Ion chromatography, Ion exchange chromatography, Method detection limit (MDL), Nitrate (ion) content, Rain, Sleet, Snow, Sulfate content, chloride/nitrate/sulfate in atmospheric wet deposition, by chemically, suppressed ion chromatography, test, ICS Number Code 07.060 (Geology. Meteorology. Hydrology), 71.040.40 (Chemical analysis)
| 1. Scope | ||||||||||||||||||||||
|
1.1 This test method is applicable to the determination of chloride, nitrate, and sulfate in atmospheric wet deposition (rain, snow, sleet, and hail) by chemically suppressed ion chromatography (1) using a two pen variable setting recorder and integrator. For additional applications refer to Test Method D4327. 1.2 The concentration ranges for this test method are listed below. The range tested was confirmed using the interlaboratory collaborative test (see Table 1 for statistical summary of the collaborative test). Range of Range Method Tested MDL (mg/L)(2) (mg/L) (mg/L) Chloride 0.03 0.09-2.0 0.15-1.36 Nitrate 0.03 0.09-5.0 0.15-4.92 Sulfate 0.03 0.09-8.0 0.15-6.521.3 The method detection limit (MDL) is based on single operator precision (2) and may be higher or lower for other operators and laboratories. The precision and bias data presented are insufficient to justify use at this low level, however, many workers have found that this test method is reliable at lower levels than those that were tested. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 9. |
||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||
|
Letzte Aktualisierung: 2026-09-08 (Zahl der Positionen: 2 300 134)
© Copyright 2026 NORMSERVIS s.r.o.