Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Open-Channel Flow Measurement of Water Indirectly at Culverts
Automatische name übersetzung:
Standard Test Method for Open-Kanal-Durchflussmessung von Wasser indirekt an Durchlässe
NORM herausgegeben am 1.1.2013
Bezeichnung normen: ASTM D5243-92(2013)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.2013
SKU: NS-30427
Zahl der Seiten: 42
Gewicht ca.: 126 g (0.28 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
floods, open-channel flow, water discharge, ICS Number Code 17.120.20 (Flow in open channels)
Significance and Use | ||||||||
5.1 This test method is particularly useful to determine the discharge when it cannot be measured directly with some type of current meter to obtain velocities and sounding equipment to determine the cross section. See Practice D3858. 5.2 Even under the best of conditions, the personnel available cannot cover all points of interest during a major flood. The engineer or technician cannot always obtain reliable results by direct methods if the stage is rising or falling very rapidly, if flowing ice or debris interferes with depth or velocity measurements, or if the cross section of an alluvial channel is scouring or filling significantly. 5.3 Under flood conditions, access roads may be blocked, cableways and bridges may be washed out, and knowledge of the flood frequently comes too late. Therefore, some type of indirect measurement is necessary. The use of culverts to determine discharges is a commonly used practice. |
||||||||
1. Scope | ||||||||
1.1 This test method covers the computation of discharge (the volume rate of flow) of water in open channels or streams using culverts as metering devices. In general, this test method does not apply to culverts with drop inlets, and applies only to a limited degree to culverts with tapered inlets. Information related to this test method can be found in ISO 748 and ISO 1070. 1.2 This test method produces the discharge for a flood event if high-water marks are used. However, a complete stage-discharge relation may be obtained, either manually or by using a computer program, for a gauge located at the approach section to a culvert. 1.3 The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Historisch
1.1.2013
Historisch
1.1.2014
Historisch
1.1.2014
Historisch
1.1.2014
Historisch
1.1.2014
Historisch
1.1.2014
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-05-12 (Zahl der Positionen: 2 199 201)
© Copyright 2025 NORMSERVIS s.r.o.