Standard Test Method for (Analytical Procedure) Determining Transmissivity of Confined Nonleaky Aquifers by Critically Damped Well Response to Instantaneous Change in Head (Slug)
Automatische name übersetzung:
Standard Test Method for ( Analytische Verfahren ) Bestimmung Lässigkeit des Aquifers durch Confined Nonleaky kritisch gedämpfte Na Reaktion auf plötzliche Änderung in der Head ( Slug )
NORM herausgegeben am 1.1.2000
Bezeichnung normen: ASTM D5881-95(2000)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.2000
SKU: NS-32929
Zahl der Seiten: 9
Gewicht ca.: 27 g (0.06 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
aquifers, aquifer tests, ground water, hydraulic conductivity, observation wells, slug test, storage, coefficient, transmissivity, ICS Number Code 07.060 (Geology. Meteorology. Hydrology)
| 1. Scope | ||||||||||||
|
1.1 This test method covers determination of transmissivity from the measurement of water-level response to a sudden change of water level in a well-aquifer system characterized as being critically damped or in the transition range from underdamped to overdamped. Underdamped response is characterized by oscillatory changes in water level; overdamped response is characterized by return of the water level to the initial static level in an approximately exponential manner. Overdamped response is covered in Guide D4043; underdamped response is covered in D5785. 1.2 The analytical procedure in this test method is used in conjunction with Guide D4043 and the field procedure in Test Method D4044 for collection of test data. 1.3 The values stated in SI units are to be regarded as standard. 1.4 Limitations--Slug tests are considered to provide an estimate of the transmissivity of an aquifer near the well screen. The method is applicable for systems in which the damping parameter, [zeta], is within the range from 0.2 through 5.0. The assumptions of the method prescribe a fully penetrating well (a well open through the full thickness of the aquifer) in a confined, nonleaky aquifer. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||
| 2. Referenced Documents | ||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-08-26 (Zahl der Positionen: 2 298 418)
© Copyright 2026 NORMSERVIS s.r.o.