Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Guide for Using Indoor Carbon Dioxide Concentrations to Evaluate Indoor Air Quality and Ventilation
Automatische name übersetzung:
Standard-Leitfaden für den Einsatz von Indoor Kohlendioxidkonzentrationen zu Raumluftqualität und Lüftung Bewerten
NORM herausgegeben am 1.10.2007
Bezeichnung normen: ASTM D6245-07
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.10.2007
SKU: NS-34374
Zahl der Seiten: 10
Gewicht ca.: 30 g (0.07 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
air change, air changes per hour, air change rate, building, carbon dioxide, indoor air quality, odor, tracer gas, ventilation, ICS Number Code 13.040.01 (Air quality in general)
| 1. Scope | ||||||||
|
1.1 This guide describes how measured values of indoor carbon dioxide (CO2) concentrations can be used in evaluations of indoor air quality and building ventilation. 1.2 This guide describes the determination of CO 2 generation rates from people as a function of body size and level of physical activity. 1.3 This guide describes the experimentally-determined relationship between CO2 concentrations and the acceptability of a space in terms of human body odor. 1.4 This guide describes the following uses of indoor CO2 concentrations to evaluate building ventilation-mass balance analysis to determine the percent outdoor air intake at an air handler, the tracer gas decay technique to estimate whole building air change rates, and the constant injection tracer gas technique at equilibrium to estimate whole building air change rates. 1.5 This guide discusses the use of continuous monitoring of indoor and outdoor CO2 concentrations as a means of evaluating building ventilation and indoor air quality. 1.6 This guide discusses some concentration measurement issues, but it does not include or recommend a method for measuring CO 2 concentrations. 1.7 This guide does not address the use of indoor CO 2 to control outdoor air intake rates. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
| 2. Referenced Documents | ||||||||
|
Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.
Aktualisierung 2x pro Monat!
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-08-14 (Zahl der Positionen: 2 293 479)
© Copyright 2026 NORMSERVIS s.r.o.