Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Specifications for Silt Fence Materials (Includes all amendments And changes 3/7/2018).
Name übersetzen
NORM herausgegeben am 1.12.2016
Bezeichnung normen: ASTM D6461/D6461M-16a
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.12.2016
SKU: NS-673307
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
geotextile, sediment control, silt fence,, ICS Number Code 59.080.70 (Geotextiles)
1. Scope | ||||||||||||||||||||||||
1.1 This specification covers requirements and test methods for geotextile fabrics and associated components used in temporary silt fence applications. Table 1 is a material purchasing specification based on AASHTO M288. Table 2 is a specification to be used in areas of high water flow. 1.2 Both specifications are applicable to the use of a geotextile as a vertical permeable interceptor designed to remove suspended soil from overland, nonconcentrated water flow. The function of a temporary silt fence is to trap and allow settlement of soil particles from sediment laden water. The purpose is to greatly limit the transport of eroded soil from construction sites and other areas affected by water runoff. Note 1: It should be noted that proper installation and
maintenance are critical for the effective functioning of silt
fence.
1.3 The tests used to characterize the silt fence are intended to ensure good workmanship and quality and are not necessarily adequate for design purposes in view of the wide variety of possible sediments and performance objectives. 1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents, therefore each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Note 2: Although the Table
1 specification should be acceptable in most erosion control
applications, it should be noted that an alternative silt fence
specification for a higher water flow rate, listed in Table 2, may be required by the engineers
in areas that are susceptible to higher water runoff; using
Table 2 specification will
minimize safety hazards such as hydroplaning in these
areas.
|
||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||
|
Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.
Aktualisierung 2x pro Monat!
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-08-27 (Zahl der Positionen: 2 213 396)
© Copyright 2025 NORMSERVIS s.r.o.