Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Methods for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Suppressed Ion Chromatography
Automatische name übersetzung:
Standard-Prüfverfahren für Bromat , Bromid, Chlorat und Chlorit im Trinkwasser von suppressierter Ionenchromatographie
NORM herausgegeben am 15.8.2008
Bezeichnung normen: ASTM D6581-08
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 15.8.2008
SKU: NS-35721
Zahl der Seiten: 21
Gewicht ca.: 63 g (0.14 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
bottled and finished drinking water, bromate, bromide, chemical suppression, chlorate, chlorite, ion chromatography, raw water, sample preservation, Bromate content, Bromide content, Chemically-suppressed ion chromatography (IC), Chlorite content, Drinking water, Ion chromatography (IC), ICS Number Code 13.060.50 (Examination of water for chemical substances)
| Significance and Use | |||||||||||||||||||||||||||||||||
|
The oxyhalides chlorite, chlorate, and bromate are inorganic disinfection by-products (DBPs) of considerable health risk concern worldwide. The occurrence of chlorite and chlorate is associated with the use of chlorine dioxide, as well as hypochlorite solutions used for drinking water disinfection. The occurrence of bromate is associated with the use of ozone for disinfection, wherein naturally occurring bromide is oxidized to bromate. Bromide is a naturally occurring precursor to the formation of bromate. |
|||||||||||||||||||||||||||||||||
| 1. Scope | |||||||||||||||||||||||||||||||||
|
1.1 This multi-test method covers the determination of the oxyhalides—chlorite, bromate, and chlorate, and bromide, in raw water, finished drinking water and bottled (non-carbonated) water by chemically and electrolytically suppressed ion chromatography. The ranges tested using this method for each analyte were as follows:
1.1.1 The upper limits may be extended by appropriate sample dilution or by the use of a smaller injection volume. Other ions of interest, such as fluoride, chloride, nitrite, nitrate, phosphate, and sulfate may also be determined using this method. However, analysis of these ions is not the object of this test method. 1.2 It is the user's responsibility to ensure the validity of these test methods for waters of untested matrices. 1.3 This test method is technically equivalent with Part B of U.S. EPA Method 300.1 , titled “The Determination of Inorganic Anions in Drinking Water by Ion Chromatography”. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
|||||||||||||||||||||||||||||||||
| 2. Referenced Documents | |||||||||||||||||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-08-03 (Zahl der Positionen: 2 291 378)