Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Measuring Viscosity at High Shear Rate by Tapered Bearing Simulator Viscometer At 100°C (Includes all amendments And changes 8/16/2017).
Automatische name übersetzung:
Standard Test Method for Messung der Viskosität bei hoher Scherrate von Tapered Bearing Simulator -Viskosimeter bei 100 ° C
NORM herausgegeben am 10.11.2001
Bezeichnung normen: ASTM D6616-01a
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 10.11.2001
SKU: NS-35899
Zahl der Seiten: 13
Gewicht ca.: 39 g (0.09 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
dynamic viscosity, high shear rate viscosity, high shear rate viscosity at 100°,C, high shear viscosity, high temperature viscosity, rotational viscometer, Tapered Bearing Simulator Viscometer, ICS Number Code 17.060 (Measurement of volume, mass, density, viscosity)
| 1. Scope | ||||
|
1.1 This test method covers the laboratory determination of the viscosity of engine oils at 100°C and 1·106s -1 using the Tapered Bearing Simulator (TBS) viscometer. Note 1—This test method is similar to Test Method D 4683 which uses the same TBS viscometer to measure high shear viscosity at 150°C. 1.2 The Newtonian calibration oils used to establish this test method range from approximately 5 to 12 mPa·s (cP) at 100°C and either the manual or automated protocol was used by each participant in developing the precision statement. The viscosity range of the test method at this temperature is from 1 mPa·s (cP) to above 25 mPa·s (cP, depending on the model of TBS. 1.3 The non-Newtonian reference oil used to establish the shear rate of 1·106s-1 for this test method has a viscosity of approximately 10 mPa·s at 100°C. 1.4 Application to petroleum products other than engine oil has not been determined in preparing the viscometric information for this test method. 1.5 This test method uses the milliPascal second (mPa·s) as the unit of viscosity. This unit is equivalent to the centiPoise (cP), which is shown in parentheses. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use. |
||||
| 2. Referenced Documents | ||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Vorschriften verwenden?
Wir bieten Ihnen Lösungen, damit Sie immer nur die gültigen (aktuellen) legislativen Vorschriften verwenden könnten.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-08-02 (Zahl der Positionen: 2 290 553)
© Copyright 2026 NORMSERVIS s.r.o.