Standard Practice for Laboratory Bias Detection Using Single Test Result from Standard Material
Automatische name übersetzung:
Standard Praxis für Labor Bias Erkennung Mit Einzel- Test- Ergebnis aus Standardmaterial
NORM herausgegeben am 1.11.2005
Bezeichnung normen: ASTM D6617-05
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.11.2005
SKU: NS-35903
Zahl der Seiten: 5
Gewicht ca.: 15 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
accepted reference value, bias, check standard, consensus, power of test, probability of bias detection, type I error, type II error, ICS Number Code 19.020 (Test conditions and procedures in general)
| Significance and Use | ||||||
|
Laboratories performing petroleum test methods can use this practice to set an acceptable tolerance zone for infrequent testing of CS or CCS material, based on ε, and a desired Type I error, for the purpose of ascertaining if the test method is being performed without bias. This practice can be used to estimate the power of correctly detecting bias of different magnitudes, using the acceptable tolerance zone set in 4.1, and hence, gain insight into the limitation of the true bias detection capability associated with this acceptable tolerance zone. With this insight, trade-offs can be made between desired Type I error versus desired bias detection capability to suit specific business needs. The CS testing activities described in this practice are intended to augment and not replace the regular statistical monitoring of test method performance as described in Practice D 6299. |
||||||
| 1. Scope | ||||||
|
1.1 This practice covers a methodology for establishing an acceptable tolerance zone for the difference between the result obtained from a single implementation of a test method on a CS and its ARV, based on user-specified Type I error, the user-established test method precision, the standard error of the ARV, and a presumed hypothesis that the laboratory is performing the test method without bias. Note 1Throughout this practice, the term user refers to the user of this practice; and the term laboratory (see ) refers to the organization or entity that is performing the test method. 1.2 For the tolerance zone established in , a methodology is presented to estimate the probability that the single test result will fall outside the zone, in the event that there is a bias (positive or negative) of a user-specified magnitude that is deemed to be of practical concern (that is, the presumed hypothesis is not true). 1.3 This practice is intended for ASTM Committee D02 test methods that produce results on a continuous numerical scale. 1.4 This practice assumes that the normal (Gaussian) model is adequate for the description and prediction of measurement system behavior when it is in a state of statistical control. Note 2While this practice does not cover scenarios in which multiple results are obtained on the same CS under site precision or repeatability conditions, the statistical concepts presented are applicable. Users wishing to apply these concepts for the scenarios described are advised to consult a statistician and to reference the CS methodology described in Practice D 6299. 1.5 Software program SiteBias, Version 1.0.1 (ADJD6617) performs the necessary calculations prescribed by this practice. |
||||||
| 2. Referenced Documents | ||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-08-02 (Zahl der Positionen: 2 290 553)
© Copyright 2026 NORMSERVIS s.r.o.