Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Practice for Laboratory Bias Detection Using Single Test Result from Standard Material
Name übersetzen
NORM herausgegeben am 1.5.2017
Bezeichnung normen: ASTM D6617-17
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.5.2017
SKU: NS-684513
Zahl der Seiten: 5
Gewicht ca.: 15 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
accepted reference value, bias, check standard, consensus, power of test, probability of bias detection, type I error, type II error,, ICS Number Code 19.020 (Test conditions and procedures in general)
Significance and Use | ||||||
4.1 Laboratories performing petroleum test methods can use this practice to set an acceptable tolerance zone for infrequent testing of CS or CCS material, based on ε, and a desired Type I error, for the purpose of ascertaining if the test method is being performed without bias. 4.2 This practice can be used to estimate the power of correctly detecting bias of different magnitudes, given the acceptable tolerance zone set in 4.1, and hence, gain insight into the limitation of the true bias detection capability associated with this acceptable tolerance zone. With this insight, trade-offs can be made between desired Type I error versus desired bias detection capability to suit specific business needs. 4.3 The CS testing activities described in this practice are intended to augment and not replace the regular statistical monitoring of test method performance as described in Practice D6299. |
||||||
1. Scope | ||||||
1.1 This practice covers a methodology for establishing an acceptable tolerance zone for the difference between the result obtained from a single implementation of a test method on a Check Standard (CS) and its ARV, based on user-specified Type I error, the user-established test method precision, the standard error of the ARV, and a presumed hypothesis that the laboratory is performing the test method without bias. Note 1: Throughout this practice, the term “user” refers to
the user of this practice, and the term “laboratory” (see
1.1) refers to the
organization or entity that is performing the test
method.
1.2 For the tolerance zone established in 1.1, a methodology is presented to estimate the probability that the single test result will fall outside the zone, in the event that the presumed hypothesis is not true and there is a bias (positive or negative) of a user-specified magnitude that is deemed to be of practical concern. 1.3 This practice is intended for ASTM Committee D02 test methods that produce results on a continuous numerical scale. 1.4 This practice assumes that the normal (Gaussian) model is adequate for the description and prediction of measurement system behavior when it is in a state of statistical control. Note 2: While this practice does not cover scenarios in which
multiple results are obtained on the same CS under site precision
or repeatability conditions, the statistical concepts presented are
applicable. Users wishing to apply these concepts for the scenarios
described are advised to consult a statistician and to reference
the CS methodology described in Practice D6299.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||
2. Referenced Documents | ||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Vorschriften verwenden?
Wir bieten Ihnen Lösungen, damit Sie immer nur die gültigen (aktuellen) legislativen Vorschriften verwenden könnten.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-04-26 (Zahl der Positionen: 2 896 057)
© Copyright 2024 NORMSERVIS s.r.o.