Standard Test Method for Determination of the Thermal Conductivity of Anode Carbons by the Guarded Heat Flow Meter Technique (Includes all amendments And changes 2/26/2024).
Name übersetzen
NORM herausgegeben am 1.1.2017
Bezeichnung normen: ASTM D6744-06(2017)e1
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.2017
SKU: NS-676311
Zahl der Seiten: 6
Gewicht ca.: 18 g (0.04 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
heat flow meter, heat flux transducer, thermal conductance, thermal conductivity, thermal resistance,, ICS Number Code 17.200.20 (Temperature-measuring instruments)
Significance and Use | ||||
5.1 This test method is designed to measure and compare thermal properties of materials under controlled conditions and their ability to maintain required thermal conductance levels. |
||||
1. Scope | ||||
1.1 This test method covers a steady-state technique for the determination of the thermal conductivity of carbon materials in thicknesses of less than 25 mm. The test method is useful for homogeneous materials having a thermal conductivity in the approximate range 1< λ < 30 W/(m·K), (thermal resistance in the range from 10 to 400 × 10−4 m2 ·K/W) over the approximate temperature range from 150 K to 600 K. It can be used outside these ranges with reduced accuracy for thicker specimens and for thermal conductivity values up to 60 W/(m·K). Note 1: It is not recommended to test graphite cathode
materials using this test method. Graphites usually have a very low
thermal resistance, and the interfaces between the specimen to be
tested and the instrument become more significant than the specimen
itself.
1.2 This test method is similar in concept to Test Methods E1530 and C518. Significant attention has been paid to ensure that the thermal resistance of contacting surfaces is minimized and reproducible. 1.3 The values stated in SI units are regarded as standard. 1.3.1 Exception—The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||
2. Referenced Documents | ||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-04-26 (Zahl der Positionen: 2 896 057)
© Copyright 2024 NORMSERVIS s.r.o.