Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Pour Point of Petroleum Products (Robotic Tilt Method)
Automatische name übersetzung:
Standard Test Method for Pour Point of Petroleum Products ( Robotic Tilt -Methode)
NORM herausgegeben am 10.7.2003
Bezeichnung normen: ASTM D6892-03
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 10.7.2003
SKU: NS-36912
Zahl der Seiten: 5
Gewicht ca.: 15 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
automatic pour point, petroleum products, pour point, robotic tilt method, ICS Number Code 75.080 (Petroleum products in general)
| Significance and Use | ||||||||
|
The pour point of a petroleum product is an index of the lowest temperature of its utility for certain applications. Flow characteristics, such as pour point, can be critical for the correct operation of lubricating systems, fuel systems, and pipeline operations. Petroleum blending operations require precise measurement of the pour point. Test results from this test method can be determined at either 1 or 3°C intervals. This test method yields a pour point in a format similar to Test Method D 97 or IP 15, when the 3°C interval results are reported. Note 2—Since some users may wish to report their results in a format similar to Test Method D 97 or IP 15 (in 3°C intervals) the precision data were derived for the 3°C intervals. For statements on bias relative to Test Method D 97 or IP 15, see the research report. This test method has comparable repeatability and better reproducibility relative to Test Method D 97 or IP 15 as measured in the 1998 interlaboratory program.5
|
||||||||
| 1. Scope | ||||||||
|
1.1 This test method covers the determination of the pour point of petroleum products by an automatic instrument that tilts the test jar to detect movement of the surface of the test specimen with an optical device, after being removed from a regulated, stepped-bath cooling jacket. 1.2 This test method is designed to cover the range of temperatures from -57 to +51°lC; however, the range of temperatures included in the 1998 interlaboratory test program only covered the temperature range from -51 to -11°C. 1.3 Test results from this test method can be determined at either 1 or 3°C testing intervals. 1.4 This test method is not intended for use with crude oils. Note 1—The applicability of this test method on residual fuel samples has not been verified. For further information on the applicability, refer to 1.4. 1.5 The values stated in SI units are regarded as standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
| 2. Referenced Documents | ||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-07-24 (Zahl der Positionen: 2 290 214)
© Copyright 2026 NORMSERVIS s.r.o.