Standard Test Method for Testing Vertical Strip Drains in the Crimped Condition (Includes all amendments And changes 8/3/2022).
Automatische name übersetzung:
Standard Test Method for Testing Vertikale Streifen Abflüsse im Crimped Zustand
NORM herausgegeben am 1.1.2014
Bezeichnung normen: ASTM D6918-09(2014)e1
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.2014
SKU: NS-37001
Zahl der Seiten: 6
Gewicht ca.: 18 g (0.04 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
constant head, crimped, flow velocity, percent change, uncrimped, vertical strip drain confined crimp test, ICS Number Code 91.060.20 (Roofs)
Significance and Use | ||||
5.1 This test method is considered satisfactory for the acceptance of commercial shipments of vertical strip drains. 5.1.1 In case of dispute arising from differences in reported test results when using this test method for acceptance testing of commercial shipments, the purchaser and the supplier should conduct comparative tests to determine if there is any statistical bias between their laboratories. Competent statistical assistance is recommended for the investigation of bias. As a minimum, the two parties should take a group of test specimens that as homogenous as possible, and that are from a lot of material of the type in question. The test specimens should be randomly assigned in numbers to each laboratory for testing. The average results from the two laboratories should be compared using Student's t-test for unpaired data and an acceptable probability level chosen by the two parties before the start of testing. If a bias is found, either its cause must be found and corrected, or the purchaser and the supplier must agree to interpret future test results in light of the known bias. 5.2 Vertical strip drains are installed in areas where it is desired to increase the rate of soil consolidation. It has been shown that as the soil around the vertical strip drain consolidates, a crimp may form in the vertical strip drain due to the movement of the drain in the area of soil consolidation. 5.3 This test method can be used to evaluate if there is any reduction in flow rate of water through the drain due to the crimping, and what effect, if any, this crimping may have on the rate of consolidation of the soil. |
||||
1. Scope | ||||
1.1 This test method is a performance test that measures the effect crimping has on the ability of vertical strip drains to transmit water parallel to the plane of the drain. 1.2 This test method is applicable to all vertical strip drains. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||
2. Referenced Documents | ||||
|
Historisch
15.2.2011
Historisch
15.2.2011
Historisch
1.4.2011
Historisch
1.5.2014
Historisch
1.12.2011
Historisch
1.6.2014
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-05-17 (Zahl der Positionen: 2 902 148)
© Copyright 2024 NORMSERVIS s.r.o.