Standard Test Method for Determination of Relative Density and Absorption of Fine, Coarse and Blended Aggregate Using Combined Vacuum Saturation and Rapid Submersion
Automatische name übersetzung:
Standard Test Methode zur Bestimmung der relativen Dichte und Absorption für Fein, Grob und Blended Aggregate mit kombinierten Vakuum-Sättigung und Rapid Untertauchen
NORM herausgegeben am 1.6.2014
Bezeichnung normen: ASTM D7370/D7370M-14
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.6.2014
SKU: NS-579633
Zahl der Seiten: 8
Gewicht ca.: 24 g (0.05 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
absorption, aggregate, apparent density, apparent relative density, blended aggregate, coarse aggregate, combined aggregate, density, fine aggregate, relative density, specific gravity,, ICS Number Code 91.100.15 (Mineral materials and products)
Significance and Use | ||||||||||||||||||||
4.1 Relative density (specific gravity) is the characteristic generally used for calculation of the volume occupied by the aggregate in various mixtures containing aggregate, including Portland cement concrete, bituminous concrete, and other mixtures that are proportioned or analyzed on an absolute volume basis. Relative density (specific gravity) is also used in the computation of voids in aggregate in Test Method C29/C29M. Relative density (specific gravity) saturated surface dry (SSD) is used if the aggregate is at SSD, that is, if its absorption has been satisfied. Conversely, the relative density (specific gravity) oven-dry (OD) is used for computations when the aggregate is dry or assumed to be dry. 4.2 Apparent density and apparent relative density (apparent specific gravity) pertain to the solid material making up the constituent particles not including the pore space within the particles which is accessible to water. 4.3 Absorption values are used to calculate the change in the mass of an aggregate due to water absorbed in the pore spaces within the constituent particles, when it is deemed that the aggregate has been in contact with water long enough to satisfy the absorption potential. The laboratory standard for absorption is that obtained after submerging dry aggregate for a prescribed period of time. Note 1: There are other test methods that have been used and
continue to be used to determine these aggregate properties:
C127 and C128. This test method may result in
values for these properties that are close to or divergent from
values from other test methods.
Note 2: The quality of the results produced by this standard
are dependent upon the competence of the personnel performing the
procedure and the capability, calibration, and the maintenance of
the equipment used. Agencies that meet the criteria of Practice
D3666 are generally
considered capable of competent and objective
testing/sampling/inspection/etc. Users of this standard are
cautioned that compliance with Practice D3666 alone does not completely assure
reliable results. Reliable results depend on many factors:
following the suggestions of Practice D3666 or similar acceptable guideline
provides a means of evaluating and controlling some of those
factors.
|
||||||||||||||||||||
1. Scope | ||||||||||||||||||||
1.1 This test method covers the determination of relative density and absorption of fine aggregates by Method A and coarse and blended aggregates by Method B. 1.2 A multi-laboratory precision and bias statement for coarse and combined aggregate tests in this standard has not been developed at this time. Therefore, this standard should not be used for acceptance or rejection of coarse and combined aggregate materials for purchasing purposes. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Some values have only SI units because inch-pound equivalents are not used in practice. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-04-28 (Zahl der Positionen: 2 896 137)
© Copyright 2024 NORMSERVIS s.r.o.