Standard Test Method for Determining Extreme Pressure Properties of Lubricating Oils Using High-Frequency, Linear-Oscillation (SRV) Test Machine
Name übersetzen
NORM herausgegeben am 1.10.2016
Bezeichnung normen: ASTM D7421-16
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.10.2016
SKU: NS-676313
Zahl der Seiten: 7
Gewicht ca.: 21 g (0.05 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
extreme pressure, lubricating oils, oscillating, SRV,, ICS Number Code 75.100 (Lubricants, industrial oils and related products)
Significance and Use | ||||||||||||||||
5.1 This laboratory test method can be used to quickly determine extreme pressure properties of lubricating oils at selected temperatures specified for use in applications where not only high-speed vibrational or start-stop motions are present with high Hertzian point contact. This test method has found wide application in qualifying lubricating oils used in constant velocity joints of front-wheel-drive automobiles, gear-hydraulic circuit, rear axles, gears and engine components. Users of this test method should determine whether results correlate with field performance or other applications. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This test method covers a procedure for determining extreme pressure properties of lubricating oils for hydraulics, gears, and engines under high-frequency linear-oscillation motion using the SRV test machine. Note 1: This test method was developed and the international
round robin tests were jointly performed with the DIN 51834 working
group. This procedure is based on the 2005 revision of Test Method
D5706 for greases and differs
regarding the stroke length and the cleaning solvent.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.
Aktualisierung 2x pro Monat!
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-05-03 (Zahl der Positionen: 2 896 946)
© Copyright 2024 NORMSERVIS s.r.o.