Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Determination of Dioctyl Sulfosuccinate in Sea Water by Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)
Automatische name übersetzung:
Standard Test Methode zur Bestimmung von Dioctylsulfosuccinat in Meerwasser durch Flüssigchromatographie / Massenspektrometrie (LC / MS / MS)
NORM herausgegeben am 1.5.2011
Bezeichnung normen: ASTM D7730-11
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.5.2011
SKU: NS-39031
Zahl der Seiten: 11
Gewicht ca.: 33 g (0.07 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
Dioctyl Sulfosuccinate , Liquid Chromatography, Mass Spectrometry, Water, ICS Number Code 71.060.50 (Salts)
Significance and Use | ||||||
DOSS is an anionic detergent that is approved by the Food and Drug Administration and is used widely as a laxative, emulsifying, solubilizing and dispersing agent, and is used in the cosmetic industry. DOSS may also be used as a dispersing agent to treat oil. DOSS may be released into the environment at levels that may be harmful to aquatic life. The US EPA aquatic life benchmark for DOSS is 40 ppb. This method has been investigated for use with reagent and sea water. |
||||||
1. Scope | ||||||
1.1 This procedure covers the determination of dioctyl sulfosuccinate (DOSS) in sea water by direct injection using liquid chromatography (LC) and detection with tandem mass spectrometry (MS/MS). This analyte is qualitatively and quantitatively determined by this method. This method adheres to selected reaction monitoring (SRM) mass spectrometry. 1.2 The Detection Verification Level (DVL) and Reporting Range for DOSS are listed in Table 1. 1.2.1 The DVL is required to be at a concentration at least 3 times below the Reporting Limit (RL) and have a signal/noise ratio greater than 3:1. Fig. 1 and Fig. 2 display the signal/noise ratio of the selected reaction monitoring (SRM) transition. 1.2.2 The reporting limit is the concentration of the Level 1 calibration standard as shown in Table 5 for DOSS, taking into account the 50% sample preparation dilution factor. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. TABLE 1 Detection Verification Level and Reporting Range
|
||||||
2. Referenced Documents | ||||||
|
Historisch
1.1.2014
Historisch
15.3.2011
Historisch
1.4.2012
Historisch
1.10.2009
Historisch
15.12.2013
Historisch
1.4.2008
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-05-05 (Zahl der Positionen: 2 198 283)
© Copyright 2025 NORMSERVIS s.r.o.