Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Measurement of Focal Spots of Industrial X-Ray Tubes by Pinhole Imaging
Automatische name übersetzung:
Standard Test Method for Messung der Brennflecken von Industrial X-Ray Tubes durch Pinhole Imaging
NORM herausgegeben am 1.1.2004
Bezeichnung normen: ASTM E1165-04
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.2004
SKU: NS-40691
Zahl der Seiten: 7
Gewicht ca.: 21 g (0.05 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
focal spots, pinhole camera, pinhole imaging, x-ray, x-ray tube, ICS Number Code 19.100 (Non-destructive testing)
| Significance and Use | ||||||||||||||
|
One of the factors affecting the quality of a radiographic image is geometric unsharpness. The degree of geometric unsharpness is dependent upon the focal size of the radiation source, the distance between the source and the object to be radiographed, and the distance between the object to be radiographed and the film. This test method allows the user to determine the focal size of the X-ray source and to use this result to establish source to object and object to film distances appropriate for maintaining the desired degree of geometric unsharpness. |
||||||||||||||
| 1. Scope | ||||||||||||||
|
1.1 This test method provides instructions for determining the length and width dimensions of line focal spots in industrial X-ray tubes (see Note 0). This determination is based on the measurement of an image of a focal spot that has been radiographically recorded with a "pinhole" projection/imaging technique. Note 1—Line focal spots are associated with vacuum X-ray tubes whose maximum voltage rating does not generally exceed 500 kV. 1.2 This test method may not yield meaningful results on focal spots whose nominal size is less than 0.3 mm [0.011 in.]. (See Note 1.) Note 2—The X-ray tube manufacturer may be contacted for nominal focal spot dimensions. 1.3 This test method may also be used to determine the presence or extent of focal spot damage or deterioration that may have occurred due to tube age, tube overloading, and the like. This would entail the production of a focal spot radiograph (with the pinhole method) and an evaluation of the resultant image for pitting, cracking, and the like. 1.4 Values stated in SI units are to be regarded as the standard. Inch-pound units are provided for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
| 2. Referenced Documents | ||||||||||||||
|
Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.
Aktualisierung 2x pro Monat!
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-04-26 (Zahl der Positionen: 2 274 794)
© Copyright 2026 NORMSERVIS s.r.o.