Standard Practice for Determination of the Specimen Area Contributing to the Detected Signal in Auger Electron Spectrometers and Some X-Ray Photoelectron Spectrometers
Automatische name übersetzung:
Standard Praxis zur Bestimmung der Probenbereich Beitrag zur erfasste Signal in Auger-Elektronenspektrometerund einige Röntgen-Photoelektronen -Spektrometer
NORM herausgegeben am 10.4.2000
Bezeichnung normen: ASTM E1217-00
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 10.4.2000
SKU: NS-40895
Zahl der Seiten: 7
Gewicht ca.: 21 g (0.05 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
Absorbed current, Computer programs, Current measurement, Deflection, Detectors, Line scan, Oscilloscope, Raster scan, Scanning, Signal detection, Specimen area, Spectrometry, Spectroscopy-auger electron (AES), Spectroscopy-x-ray photoelectron, Surface analysis-spectrochemical analysis, Topography, Voltage, Waveform, specimen area contributing to detected signal in, photoelectron/auger-electron spectroscopy, practice, ICS Number Code 71.040.50 (Physicochemical methods of analysis)
| 1. Scope | ||||||
|
1.1 This practice describes methods for determining the specimen area contributing to the detected signal in X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES) when this area is defined by the electron collection lens/aperture system. It is recommended as a useful means of determining the observed specimen area for different conditions of spectrometer operation, verifying adequate specimen alignment, and characterizing the imaging properties of the electron energy analyzer. 1.2 This practice is intended only for spectrometers in which the specimen area excited by X-ray or electron beams is or can be made larger than the specimen area viewed by the analyzer. It is assumed that, under normal conditions of operation, the specimen is excited by a beam of X rays or electrons that can be considered to have a uniform intensity over the specimen area viewed by the analyzer, and the specimen is homogeneous and uniform over the observed area. 1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
| 2. Referenced Documents | ||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-04-22 (Zahl der Positionen: 2 274 512)
© Copyright 2026 NORMSERVIS s.r.o.