Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Determination of Lead in Nickel Alloys by Graphite Furnace Atomic Absorption Spectrometry
Automatische name übersetzung:
Standard Test Methode zur Bestimmung von Blei in Nickellegierungen von Graphitofen -Atomabsorptionsspektrometrie
NORM herausgegeben am 15.7.2009
Bezeichnung normen: ASTM E1834-09
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 15.7.2009
SKU: NS-43246
Zahl der Seiten: 4
Gewicht ca.: 12 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
atomic absorption spectrometry, GF-AAS, graphite furnace atomic absorption spectrometry, lead content, nickel alloys, trace element determination, Atomic absorption spectrometry (AAS), Electrothermal atomic absorption spectrometry, Flameless atomic absorption spectrometry, Graphite furnace atomic absorption spectrometry (GFAAS), Lead content, Lead screening testing, Nickel alloys, Trace elements--spectrochemical analysis, ICS Number Code 77.120.40 (Nickel, chromium and their alloys)
Significance and Use | ||||||||||||||||||||
This test method is used for the determination of trace levels of lead in nickel alloys by GF-AAS to check compliance with compositional specifications. It is assumed that the procedure will be performed by trained analysts capable of performing common laboratory practices skillfully and safely. It is expected that the work will be performed in a properly equipped laboratory and proper waste disposal procedures will be followed. Appropriate quality control practices must be followed such as those described in Guide E 882. |
||||||||||||||||||||
1. Scope | ||||||||||||||||||||
1.1 This test method covers the determination of lead in nickel alloys in the concentration range 0.00005 % to 0.001 % by graphite furnace atomic absorption spectrometry (GF-AAS). Note 1—If this test method is used to test materials having contents less than 0.0001 % lead, users in different laboratories may experience more than the usual 5 % risk that their results will differ by more than 50 % relative error. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazards associated with the use of this test method, see Practices E 50. |
||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-05-15 (Zahl der Positionen: 2 900 316)
© Copyright 2024 NORMSERVIS s.r.o.