Standard Test Method for Determining Oxidation Induction Time of Hydrocarbons by Differential Scanning Calorimetry
Automatische name übersetzung:
Standard-Testverfahren zur Bestimmung der Oxidationsinduktionszeit der Kohlenwasserstoffe mit Hilfe der Differentialscanningkalorimetrie
NORM herausgegeben am 1.9.2008
Bezeichnung normen: ASTM E1858-08
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.9.2008
SKU: NS-43340
Zahl der Seiten: 6
Gewicht ca.: 18 g (0.04 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
differential scanning calorimetry, hydrocarbons, isothermal temperature, oxidation, oxidation induction time, oxidative stability, pressure differential scanning calorimetry, Differential scanning calorimetry (DSC), Hydrocarbons, Isothermal conditions/testing, Oxidation induction time (OIT), Oxidation testing--petroleum products, Pressure differential scanning calorimetry (PDSC)
| Significance and Use | ||||||||||||||||||||||||
|
Oxidative induction time is a relative measure of the degree of oxidative stability of the material evaluated at the isothermal temperature of the test. The presence, quantity or effectiveness of antioxidants may be determined by this method. The OIT values thus obtained may be compared from one hydrocarbon to another or to a reference material to obtain relative oxidative stability information. Typical uses include the oxidative stability of edible oils and fats (oxidative rancidity), lubricants, greases, and polyolefins. |
||||||||||||||||||||||||
| 1. Scope | ||||||||||||||||||||||||
|
1.1 This test method describes the determination of the oxidative properties of hydrocarbons by differential scanning calorimetry or pressure differential scanning calorimetry and is applicable to hydrocarbons that oxidize exothermically in their analyzed form. 1.2 Test Method A— A differential scanning calorimeter (DSC) is used at ambient pressure, for example, about 100 kPa of oxygen. 1.3 Test Method B— A pressure DSC (PDSC) is used at high pressure, for example, 3.5 MPa (500 psig) oxygen. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This test method is related to ISO 11357–6 but is different in technical content. This test method is related to CEC L-85–T but includes additional experimental conditions. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Note 5 and Note 13. |
||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-12-26 (Zahl der Positionen: 2 253 153)
© Copyright 2025 NORMSERVIS s.r.o.