Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Analysis of Ni-Base Alloys by Wavelength Dispersive X-Ray Fluorescence Spectrometry
Name übersetzen
NORM herausgegeben am 1.10.2019
Bezeichnung normen: ASTM E2465-19
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.10.2019
SKU: NS-976117
Zahl der Seiten: 11
Gewicht ca.: 33 g (0.07 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Non-destructive testing of metalsTitanium and titanium alloys
Keywords:
Ni-base alloys, spectrometric analysis, X-ray fluorescence,, ICS Number Code 77.040.20 (Non-destructive testing of metals),77.120.50 (Titanium and titanium alloys)
Significance and Use | ||||||||||||||||||||||||||||
5.1 This procedure is suitable for manufacturing control and for verifying that the product meets specifications. It provides rapid, multi-element determinations with sufficient accuracy to assure product quality. The analytical performance data included may be used as a benchmark to determine if similar X-ray spectrometers provide equivalent precision and accuracy, or if the performance of a particular spectrometer has changed. |
||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||
1.1 This test method covers the analysis of Ni-base alloys by wavelength dispersive X-ray Fluorescence Spectrometry for the determination of the following elements:
Note 1: Unless exceptions are noted, ranges can be extended by
the use of suitable reference materials. Once these element ranges
are extended they must be verified by some experimental means. This
could include but not limited to Gage Repeatability and
Reproducibility studies, Interlaboratory Round Robin studies, or
both. Once these studies are completed, they will satisfy the
ISO/IEC 17025 requirements for capability.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-05-08 (Zahl der Positionen: 2 198 869)
© Copyright 2025 NORMSERVIS s.r.o.