Standard Practice for Measuring and Calculating Building Loss Features That Take Up Floor Area in Buildings
Automatische name übersetzung:
Standard Praxis zur Messung und Berechnung von Gebäuden Loss Funktionen, die Take Up Wohnfläche in Gebäude
NORM herausgegeben am 1.4.2008
Bezeichnung normen: ASTM E2619-08
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.4.2008
SKU: NS-45743
Zahl der Seiten: 11
Gewicht ca.: 33 g (0.07 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
ctual loss, area measurement, building, building elements, building feature, building loss factor, capability, column size, effective loss, exterior gross area, facility, facility occupants, feature, floor area, floor area measurement, floor load, function, interior encroachment, major vertical penetrations, office, performance, perimeter encroachment, rating, rating scale, requirements, restricted area, service area, serviceability, ICS Number Code 91.010.30 (Technical aspects)
Significance and Use | ||||||
Use this standard to identify and measure the amount of actual and effective floor area that will be unavailable to occupants for the placement of people’s workplaces, furniture, and equipment or for circulation. This standard is not intended for use for regulatory purposes, nor for fire hazard assessment, nor for fire risk assessment. |
||||||
1. Scope | ||||||
1.1 This practice specifies how to measure certain characteristics of a building, known as building loss features, inside the exterior gross area of a floor and how to calculate the amount of actual and effective floor area that will be not be available for the placement of people’s workplaces, furniture, equipment, or for circulation, if using standard furnishings and orthogonal furniture systems. 1.2 This practice can be used to specify a performance requirement to limit the amount of floor area that may be taken up by building loss features. 1.3 This practice can be used to assess how well a design(s) for an office facility meets a performance requirement regarding floor area. 1.4 This practice can be used to assess how well a constructed office building has met a performance requirement regarding floor area. 1.5 This practice is not intended for and not suitable for use for regulatory purposes, fire hazard assessment, and fire risk assessment. 1.6 Users of this standard practice should recognize that, in some situations, the amount of certain actual and effective floor area losses may be mitigated to some degree at some cost by custom-tailoring spaces and creating specially fitted furnishings and carpentry to get some value from space which would not otherwise be usable. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
2. Referenced Documents | ||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-08-25 (Zahl der Positionen: 2 213 294)
© Copyright 2025 NORMSERVIS s.r.o.