Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Determination of the Spectral Mismatch Parameter Between a Photovoltaic Device and a Photovoltaic Reference Cell (Includes all amendments And changes 12/31/2010).
Automatische name übersetzung:
Standard -Testverfahren für die Bestimmung der spektralen Parameter Mismatch zwischen einer photovoltaischen Vorrichtung und einer photovoltaischen Referenzzelle
NORM herausgegeben am 1.9.2005
Bezeichnung normen: ASTM E973-05a
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.9.2005
SKU: NS-48663
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
cell, mismatch, photovoltaic, reference, solar, spectral, testing, ICS Number Code 27.160 (Solar energy engineering)
Significance and Use | ||||||||||||||||||||
The calculated error in the photovoltaic device current determined from the spectral mismatch parameter can be used to determine if a measurement will be within specified limits before the actual measurement is performed. The spectral mismatch parameter also provides a means of correcting the error in the measured device current due to spectral mismatch. 5.2.1 The spectral mismatch parameter is formulated as the fractional error in the short-circuit current due to spectral differences.3 ,4 5.2.2 Error due to spectral mismatch can be corrected by dividing the measured photovoltaic cell current by M, a procedure used in Test Methods E 948 and E 1036 |
||||||||||||||||||||
1. Scope | ||||||||||||||||||||
1.1 This test method covers a procedure for the determination of a spectral mismatch parameter used in performance testing of photovoltaic devices. 1.2 The spectral mismatch parameter is a measure of the error, introduced in the testing of a photovoltaic device, caused by mismatch between the spectral responses of the photovoltaic device and the photovoltaic reference cell, as well as mismatch between the test light source and the reference spectral irradiance distribution to which the photovoltaic reference cell was calibrated. Examples of reference spectral irradiance distributions are Tables E 490 or G 159. 1.3 The spectral mismatch parameter can be used to correct photovoltaic performance data for spectral mismatch error. 1.4 This test method is intended for use with linear photovoltaic devices. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-05-16 (Zahl der Positionen: 2 902 054)
© Copyright 2024 NORMSERVIS s.r.o.