Standard Test Method for Calibration of Liquid-Borne Particle Counters for Submicrometer Particle Sizing (Withdrawn 2002) (Includes all amendments And changes 2/18/2021).
Automatische name übersetzung:
Standard Test Method for Kalibrierung von flüssigkeitsgetragenen Partikelzähler für Submikrometer Partikelmessung (Withdrawn 2002)
NORM herausgegeben am 1.1.1994
Bezeichnung normen: ASTM F1226-89(1994)e1
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.1994
SKU: NS-49565
Zahl der Seiten: 5
Gewicht ca.: 15 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
Calibration-particle analysis instrumentation, Calibration-semiconductor analysis instrumentation, liquid-borne particle counters for submicrometer particle sizing, test,, Chemicals, Cleanliness, Electronic materials/applications, Light-transmission and reflection, Liquids, Mechanical manufacturing devices, Optical materials/properties/tests-semiconductors, Particle counters, Pharmaceutical industry, Size, Spherical particles, Submicrometer particle sizing, Suspension tests
| 1. Scope |
|
1.1 This test method describes a procedure for establishing the sizing accuracy of an automatic, optical liquid-borne single particle counter, using light scattering automatic particle counter (APC). This test method is directed at determining the sizing accuracy of the APC when it is used to measure a challenge suspension of precisely-sized spherical isotropic particles, particularly those sized at and below 1 [mu]m in diameter. 1.2 The particle size parameter that is reported is the equivalent diameter based on the projected area of an isotropic spherical particle of known composition suspended in a liquid that is optically different from the suspended particle. Particles in the size range of 0.1 [mu]m and 5 [mu]m are used for calibration in this procedure. 1.3 This test method does not provide a procedure for APC counting accuracy calibration, since that procedure is available in Practice F658. However, some knowledge of APC maximum concentration capability is necessary in order to avoid introduction of sizing errors as a result of excessive particle concentration during the sizing calibration procedure. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For hazard statement, see Section 8. |
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Vorschriften verwenden?
Wir bieten Ihnen Lösungen, damit Sie immer nur die gültigen (aktuellen) legislativen Vorschriften verwenden könnten.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-12-18 (Zahl der Positionen: 2 252 678)
© Copyright 2025 NORMSERVIS s.r.o.