Standard Test Methods for Photoluminescence Analysis of Single Crystal Silicon for III-V Impurities (Withdrawn 2003)
Automatische name übersetzung:
Standard-Prüfverfahren für Photolumineszenzanalyse aus einkristallinem Silizium für die III-V- Verunreinigungen (Withdrawn 2003)
NORM herausgegeben am 10.6.2000
Bezeichnung normen: ASTM F1389-00
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 10.6.2000
SKU: NS-50130
Zahl der Seiten: 6
Gewicht ca.: 18 g (0.04 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
aluminum, arsenic, boron, dopant, impurities, phosphurus, photoluminescence, silicon, ICS Number Code 29.045 (Semiconducting materials)
1. Scope |
This standard was transferred to SEMI (www.semi.org) May 2003 1.1 These test methods cover the simultaneous determination of electrically active boron, phosphorus, arsenic, and aluminum content in low-dislocation mono-crystalline silicon. 1.2 These test methods can be used for samples that have majority dopant densities between approximately 1 X 1011 and 5 X 1015 atoms/cm3. 1.3 The concentrations obtained using these test methods are based on an empirically determined relationship of the logarithm of the concentration to the logarithm of specific luminescence line-intensity ratios. 1.4 The empirical relationship established assumes a constant sample excitation level for all measurements on a given instrument. 1.5 To accommodate differences in instrumentation, two methods are included in this proposal. "Test Method A" refers to procedures appropriate for dispersive infrared spectrophotometers operating under the high sample excitation conditions and "Test Method B" refers to procedures appropriate for Fourier transform instruments operating under low excitation conditions. 1.5.1 Typical calibration curves for each test method are provided. These curves are modified for each instrument using the analysis of standard samples as reference data. Once modified, the curves for a given instrument should produce sample dopant density values that agree with other similarly operated instruments using the same test method. Data obtained using Test Method A may not agree with data obtained using Test Method B, hence values must be reported with reference to the test method used. 1.6 Many laboratories use photoluminescence to analyze epitaxial layers. However this application encounters many variables and the underlying physics is not fully understood; hence these test methods do not attempt to outline standard practices regarding such analysis. 1.7 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Vorschriften verwenden?
Wir bieten Ihnen Lösungen, damit Sie immer nur die gültigen (aktuellen) legislativen Vorschriften verwenden könnten.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-10-31 (Zahl der Positionen: 2 208 647)
© Copyright 2024 NORMSERVIS s.r.o.