Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Specification for Humidifiers for Medical Use-Part 1: General Requirements for Active Humidification Systems (Withdrawn 2013)
Automatische name übersetzung:
Standard-Spezifikation für Luftbefeuchter für den medizinischen Einsatz - Teil 1: Allgemeine Festlegungen für aktive Befeuchtung Systems ( Withdrawn 2013)
NORM herausgegeben am 1.6.2004
Bezeichnung normen: ASTM F1690-96(2004)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.6.2004
SKU: NS-51178
Zahl der Seiten: 17
Gewicht ca.: 51 g (0.11 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
humidifiers, medical use, active humidification systems, ICS Number Code 11.040.10 (Anaesthetic, respiratory and reanimation equipment), 11.140 (Hospital equipment), 91.140.30 (Ventilation and air-conditioning systems)
1. Scope | ||||||||||||
1.1 The requirements given in Clause 1 of the General Standard apply with the following additions and modifications: 1.1.1 Replace with the following: 1.1.1.1 This specification includes requirements for the safety and performance of active vaporizing and nebulizing humidification systems, as defined in 3.1.6, suitable for inclusion in breathing systems (both intubated and non-intubated patients). 1.1.1.2 This specification also includes requirements for breathing tubes, including heated breathing tubes (heated-wire breathing circuits), and devices intended to control these heated breathing tubes, heated breathing tube controllers. 1.1.1.3 Heat and moisture exchangers (HMEs) are outside the scope of this specification. However, it is recognized that their safety and performance may affect that of humidification systems. Numerous studies have been published citing the benefits and risks of HMEs used in conjunction with humidification systems. It is advisable to review the instructions for use provided with the humidification systems and HMEs and the available literature for more details. 1.1.1.4 Devices commonly referred to as "room humidifiers," humidifiers used in heating, ventilation, and air-conditioning systems and humidifiers used to condition the environment within infant incubators are outside the scope of this specification. 1.1.1.5 It has not been found possible to include guidance on the matter of droplet size in the case of nebulizing humidifiers. 1.1.1.6 Gas-powered nebulizers used for the delivery of drugs to patients through their respiratory system are outside the scope of this specification. 1.1.1.7 Appendices in this specification are not mandatory unless made so by an explicit statement in the main text. 1.2 The values stated in SI units are to be regarded as the standard. |
||||||||||||
2. Referenced Documents | ||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-07-04 (Zahl der Positionen: 2 207 347)
© Copyright 2025 NORMSERVIS s.r.o.