Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Measurement of Magnetically Induced Torque on Passive Implants in the Magnetic Resonance Environment
Automatische name übersetzung:
Standard Test Method for Messung der magnetisch induzierten Drehmoment auf Passive Implantate in der Magnet-Resonanz- Umwelt
NORM herausgegeben am 1.1.2004
Bezeichnung normen: ASTM F2213-04
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.2004
SKU: NS-53215
Zahl der Seiten: 7
Gewicht ca.: 21 g (0.05 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
force, magnetic, implant, metals (for surgical implants), MRI (magnetic resonance imaging), MR safety, torque, magnetic, ICS Number Code 17.220.20 (Measurement of electrical and magnetic quantities)
1. Scope | ||||||||||
1.1 This test method covers the measurement of the magnetically induced torque produced by the static magnetic field in the magnetic resonance environment on medical devices and the comparison of that torque to the equivalent torque applied by the gravitational force to the implant. 1.2 This test method does not address other possible safety issues which include but are not limited to issues of magnetically induced force due to spatial gradients in the static magnetic field, RF heating, induced heating, acoustic noise, interaction among devices, and the functionality of the device and the MR system. 1.3 The torque considered here is the magneto-static torque due to the interaction of the MRI static magnetic field with the magnetization in the implant. The dynamic torque due to interaction of the static field with eddy currents induced in a rotating device is not addressed in this test method. Currents in lead wires may induce a torque as well. 1.4 The sensitivity of the torque measurement apparatus must be greater than 1/10 the "gravity torque," the product of the device's maximum linear dimension and its weight. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-07-25 (Zahl der Positionen: 2 209 786)
© Copyright 2025 NORMSERVIS s.r.o.