Standard Specification for Minimum Performance and Safety Requirements for Resuscitators Intended for Use With Humans (Withdrawn 2007)
Automatische name übersetzung:
Standard-Spezifikation für Mindest Leistungs- und Sicherheitsanforderungen für Beatmungsbeutel zur bestimmungsgemäßen Verwendung beim Menschen (Withdrawn 2007)
NORM herausgegeben am 1.1.1999
Bezeichnung normen: ASTM F920-93(1999)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.1999
SKU: NS-56953
Zahl der Seiten: 15
Gewicht ca.: 45 g (0.10 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
Adult resuscitators, Child resuscitators, Electrically-powered resuscitators, Gas-powered resuscitators, Infants, Lung ventilation, Operator-powered resuscitators, Performance-medical materials/applications, Pulmonary resuscitators, Safety precautions-medical materials/applications, resuscitators for use with humans- minimum performance/safety, requirements, spec, ICS Number Code 11.040.10 (Anaesthetic, respiratory and reanimation equipment)
1. Scope |
1.1 This specification covers ventilatory resuscitators, that is, small portable ventilators intended to be used in emergencies both outside and inside hospitals. These devices are intended for use by medical personnel and for emergency use by personnel with varying degrees of training. They are intended to be used at the site of an emergency and during patient transport. Resuscitators intended for use on all age groups are included within the scope of this specification. 1.1.1 This specification does not intend to discourage or impede future innovation or development of resuscitators. 1.2 The effective and safe use of a resuscitator is determined not only by the performance of the resuscitator, but also by the skill of the operator. This specification does not describe the content of the training programs to develop such skill and does not state who should or should not use a resuscitator. This will be determined by the organizations involved in teaching resuscitation. 1.2.1 In certain countries, resuscitators are intended for use by nontrained personnel and lower pressure limits are set. Some countries also reserve the use of automatic gas-powered resuscitators to trained individuals under medical supervision. This specification is not intended to conflict with these established practices. 1.3 Annex A1 details test methods, while Annex A2 provides tables of resistances and compliances required to set up the test lung. Annex A3 gives a rationale for various clauses in this specification and is included to provide additional insight into the reasoning that led to the requirements and recommendations that have been given. Annexes A4 and A5 provide advice concerning materials to be used in resuscitators and face masks. 1.4 The values stated in SI units are to be regarded as the standard. 1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-05-19 (Zahl der Positionen: 2 201 616)
© Copyright 2025 NORMSERVIS s.r.o.