Standard Guide for Corrosion Monitoring in Laboratories and Plants with Coupled Multielectrode Array Sensor Method
Name übersetzen
NORM herausgegeben am 1.5.2022
Bezeichnung normen: ASTM G217-16(2022)
Ausgabedatum normen: 1.5.2022
SKU: NS-1057090
Zahl der Seiten: 11
Gewicht ca.: 33 g (0.07 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
CMAS, corrosion monitoring, coupled multielectrode, coupled multielectrode array sensor, crevice corrosion, localized corrosion monitoring, on-line corrosion monitoring, pitting corrosion,, ICS Number Code 19.040 (Environmental testing)
| Significance and Use | ||||||||||||||||||
|
4.1?Guide G96 describes a linear-polarization method and an electrical resistance method for online monitoring of corrosion in plant equipment without the need to enter the system physically to withdraw coupons. These two online monitoring techniques are useful in systems in which process upsets or other problems can create corrosive conditions. An early warning of corrosive attack can permit remedial action before significant damage occurs to process equipment. The two methods described in Guide G96 are suitable for uniform corrosion, but may not be sensitive enough for non-uniform corrosion, especially localized corrosion. This guide describes a new method for monitoring non-uniform corrosion, especially localized corrosion. 4.2?The CMAS technique measures the net anodic current or net cathodic current from each of the individual electrodes (Iaex or FIG. 1?Principle of CMAS Probe Note 1:?The upper section shows the electron flows from the
corroding area to the less corroding areas inside a metal when
localized corrosion takes place; the lower section shows the
electron flows after the anodic and cathodic areas are separated
into individual small electrodes and coupled through an external
circuit that measures the anodic current (Iaex) and cathodic
current (4.3?Unlike uniform corrosion, the rate of
non-uniform corrosion, especially localized corrosion, can vary
significantly from one area to another area of the same metal
exposed to the same environment. Allowance shall be made for such
variations when the measured non-uniform corrosion rate is used to
estimate the penetration of the actual metal structure or the
actual wall of process equipment. This variability is less critical
when relative changes in corrosion rate are to be detected, for
example, to track the effectiveness of corrosion inhibitors in an
inhibited system.
4.4?The same as the method described in Guide G96, the CMAS technique described in this guide provides a technique for determining corrosion rates without the need to enter the system physically to withdraw coupons as required by the methods described in Guide G4. 4.5?The same as the methods described in Guide G96, the CMAS technique is useful in systems in which process upsets or other problems can create corrosive conditions. An early warning of corrosive attack can permit remedial action before significant damage occurs to process equipment. 4.6?The CMAS technique provides the instantaneous corrosion rate within 10 s to 40 s making it suitable for automatic corrosion inhibitor dosing control. 4.7?The CMAS technique is an online technique and may be used to provide real-time measurements for internal corrosion of pipelines and process vessels, external corrosion of buried pipes and structures, and atmospheric corrosion of metal structures. |
||||||||||||||||||
| 1. Scope | ||||||||||||||||||
|
1.1?This guide outlines the procedure for conducting corrosion monitoring in laboratories and plants by use of the coupled multielectrode array sensor (CMAS) technique. 1.2?For plant applications, this technique can be used to assess the instantaneous non-uniform corrosion rate, including localized corrosion rate, on a continuous basis, without removal of the monitoring probes, from the plant. 1.3?For laboratory applications, this technique can be used to study the effects of various testing conditions and inhibitors on non-uniform corrosion, including pitting corrosion and crevice corrosion. 1.4?UnitsThe values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. 1.5?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2026-08-04 (Zahl der Positionen: 2 291 378)
© Copyright 2026 NORMSERVIS s.r.o.