Gas-fired endothermic engine driven heat pumps - Part 1: Terms and definitions

Name übersetzen

NORM herausgegeben am 1.4.2024


Sprache
Realisierung
ZugänglichkeitAUF LAGER
Preis21.60 ohne MWS
21.60

Informationen über die Norm:

Bezeichnung normen: ČSN EN 16905-1
Zeichen: 061530
Katalog-Nummer: 518796
Ausgabedatum normen: 1.4.2024
SKU: NS-1169939
Zahl der Seiten: 52
Gewicht ca.: 156 g (0.34 Pfund)
Land: Tschechische technische Norm
Kategorie: Technische Normen ČSN

Die Annotation des Normtextes ČSN EN 16905-1 (061530):

This part of the EN 16905 series specifies the terms and definitions for the rating and performance calculation of gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery, to be used outdoors. This document specifies the terms and definitions. This document is intended to be used in conjunction with the following standards: - EN 16905-2:- on safety; - EN 16905-3:- on test conditions; - EN 16905-4:- on the requirements, test conditions and test methods; - EN 16905-5:2022 on the calculation of seasonal performances in heating and cooling mode; - the heat pump standards, EN 14511-2, EN 14511-3 and EN 14825. This document only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions. This document only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437. This document only applies to appliances: a) having gas fired endothermic engines under the control of fully automatic control systems; b) having closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated; c) where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation; d) where the maximum operating pressure in the: 1) heating water circuit (if installed) does not exceed 6 bar, 2) domestic hot water circuit (if installed) does not exceed 10 bar. This document applies to GEHP appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery. This document is applicable to GEHP appliances that are intended to be type tested. Requirements for GEHP appliances that are not type tested would need to be subject to further consideration

Empfehlungen:

Aktualisierung der technischen Normen

Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.

Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.




Cookies Cookies

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.

Sie können die Zustimmung verweigern hier.

Hier können Sie Ihre Cookie-Einstellungen nach Ihren Wünschen anpassen.

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können.