ČSN EN 16909 (834743)

Ambient air - Measurement of elemental carbon (EC) and organic carbon (OC) collected on filters

Name übersetzen

NORM herausgegeben am 1.9.2017


Sprache
Realisierung
ZugänglichkeitAUF LAGER
Preis21.60 ohne MWS
21.60

Informationen über die Norm:

Bezeichnung normen: ČSN EN 16909
Zeichen: 834743
Katalog-Nummer: 502723
Ausgabedatum normen: 1.9.2017
SKU: NS-693121
Zahl der Seiten: 60
Gewicht ca.: 180 g (0.40 Pfund)
Land: Tschechische technische Norm
Kategorie: Technische Normen ČSN

Kategorie - ähnliche Normen:

Ambient atmospheres

Die Annotation des Normtextes ČSN EN 16909 (834743):

This European Standard is applicable for the measurement of elemental carbon (EC) and organic carbon (OC) following the requirement for all EU member states to measure EC and OC in particulate matter from June 2010 at background sites according to the Council Directive 2008/50/EC on ambient air quality and cleaner air for Europe [1]. This European Standard describes the analytical procedures for determining EC and OC on quartz fibre filters as µg/cm2, and the subsequent calculation of concentrations as µg/m3. Sampling onto filters is to be done in accordance with EN 12341:2014 for PM2,5. The sampling process determines the size fraction of the particulate matter, the retention of semi-volatile material, and uptake/loss of volatile organic compounds on the filter at the time of sampling. The same analysis method may also be used for smaller size fractions than PM2,5. Any possible additional artefacts for larger particles, e.g. pyrolysis or higher concentrations of carbonates, should be assessed. The scope includes rural background and urban background sites. The measurement method can also be applied to other site types, provided that the measurement range given below is not exceeded. The use of this standard at all site types allows the assessment of additional exposure of people in urban areas as stated in the objectives of the council directive and to achieve coherence in the European approach. The applicable concentration range of the proposed method is limited by the optical correction and instrument applied in the analysis of EC and OC. This method was validated from 0,2 µg CEC/cm2 and 1,8 µg COC/cm2 to 38 µg CEC/cm2 and 49 µg COC/cm2 in the laboratory and to 16 µg CEC/cm2 and 45 µg COC/cm2 in the laboratory validation exercise and in the field validation exercise

Empfehlungen:

EEviZak – alle Gesetze einschließlich ihrer Evidenz in einer Stelle

Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.
Aktualisierung 2x pro Monat!

Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.




Cookies Cookies

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.

Sie können die Zustimmung verweigern hier.

Hier können Sie Ihre Cookie-Einstellungen nach Ihren Wünschen anpassen.

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können.