ČSN EN 1993-1-7-ed.2 (731401)

Eurocode 3 - Design of steel structures - Part 1-7: Plate assemblies with elements under transverse loads

Name übersetzen

NORM herausgegeben am 1.10.2025


Sprache
Realisierung
ZugänglichkeitAUF LAGER
Preis24.40 ohne MWS
24.40

Informationen über die Norm:

Bezeichnung normen: ČSN EN 1993-1-7-ed.2
Zeichen: 731401
Katalog-Nummer: 521584
Ausgabedatum normen: 1.10.2025
SKU: NS-1241305
Zahl der Seiten: 84
Gewicht ca.: 283 g (0.62 Pfund)
Land: Tschechische technische Norm
Kategorie: Technische Normen ČSN

Kategorie - ähnliche Normen:

Technical aspectsSteel structures

Die Annotation des Normtextes ČSN EN 1993-1-7-ed.2 (731401):

provides rules for the structural design of assemblies of unstiffened and stiffened steel plates whose elements are under predominantly distributed transverse loads.

2) EN 1993-1-7 is applicable to containment structures such as silos, tanks, digesters and lock gates, where the external actions chiefly act transversely on their individual plates or panels. Where a plate or panel under bending is additionally subject to membrane forces that have a significant effect on the resistance, this document covers assessment of the resistance through its computational analysis procedures.

3) EN 1993-1-7 is applicable to structures with rectangular, trapezoidal or triangular component plate segments, each with one axis of symmetry.

4) EN 1993-1-7 does not apply to plates or panels where the dominant structural resistance require-ment relates to membrane forces in the plates (for these, see EN 1993-1-5).

5) EN 1993-1-7 does not apply to plates or panels whose curvature (out of flatness) exceeds that defined in 1.1(12). For such curved plates, see EN 1993-1-6.

6) EN 1993-1-7 does not apply to circular or annular plates. For such plates, see EN 1993-1-6.

7) EN 1993-1-7 does not apply to cold-formed sheeting. For such plates, see EN 1993-1-3.

8) This document is only concerned with the requirements for design of plates and plate assemblies against the ultimate limit states of:

  • - plastic failure;
  • - cyclic plasticity;
  • - buckling;
  • - fatigue.
  • 9) Overall equilibrium of the structure (sliding, uplifting, or overturning) is not included in this docu-ment. Special considerations for specific applications are available in the relevant applications parts of EN 1993.
  • 10) The rules in this document refer to plate assemblies that are fabricated using unstiffened or stiffened plates or panels. The document is also applicable to the design of individual plates or panels that are predominantly subject to actions transverse to the plane of each plate. Both frictional actions on the plate surface and forces imposed by adjacent components of the plate assembly also induce in-plane actions in each plate.
  • 11) This document gives algebraic rules and guidance to account for bending with small membrane forces in the individual plates or panels. Where an unstiffened or stiffened plate or panel is subject to significant magnitudes of both bending and in-plane forces, the computational analysis procedures of this document apply.

12) Where no application part defines a different range, this document applies to structures within the following limits:

  • - design metal temperatures within the range -50 °C to +100 °C;
  • - the geometry of individual plate segments is limited to rectangular, triangular and trapezoidal sha-pes with b/t greater than 20, or b1/t greater than 20, as appropriate (see Figure 3.2);

Single plate elements are treated as flat where the deviation from flatness e0 meets the condition (see Figure 9.1). Where this criterion is not met, the plate or plate assembly is considered to be a shell panel (see EN 1993-1-6). 00,750et<=

Assumptions:

  • 1) Unless specifically stated, the provisions of EN 1990, EN 1991 (all parts) and EN 1993 (all parts) apply.

2) The design methods given in EN 1993-1-7 are applicable if:

  • - the execution quality is as specified in EN 1090-2, and
  • - the construction materials and products used are as specified in the relevant parts of EN 1993 (all parts), or in the relevant material and product specifications.
  • () The provisions in this document apply to materials that satisfy the brittle fracture provisions given in EN 1993-1-4 and EN 1993-1-10.
  • 4) In this document, it is assumed that wind loading, seismic actions and bulk solids flow can, in general, be treated as quasi-static actions.
  • 5) Dynamic effects are treated in other relevant application parts of EN 1993 or EN 1998, including the consequences for fatigue. The stress resultants arising from dynamic behaviour are treated in this part as quasi-static

Empfehlungen:

Aktualisierung der technischen Normen

Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.

Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.




Cookies Cookies

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.

Sie können die Zustimmung verweigern hier.

Hier können Sie Ihre Cookie-Einstellungen nach Ihren Wünschen anpassen.

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können.